Installing Cable Assemblies
22
309738L
Installing Cable Assemblies
Fluid Module Cables
Operations Cable (13) -
This cable carries signals
between the fluid module and the control unit. The
applicator solenoid, V/P valve, pressure transducer and
flow meter signals are carried through this cable.
Automation I/O Cable (17) -
This cable carries signals
between the automation controller and the PrecisionFlo
LT control unit.
Maximum recommended length of both the opera-
tions and automation cable is 125 ft. (38.1 m).
Connecting the Operations Cable
Operation cables are offered in three lengths (25, 60,
and 125 ft.) and three flexibilities (see page 6 for cable
options.)
To connect the operation cable between the control unit
and fluid module do the following:
1.
Locate the receptacle on the top of the control unit.
See Fig. 8.
2.
Connect the operation cable to the control unit rev-
ceptable.
3.
Locate the receptacle on the fluid module junction
box.
4.
Route the operation cable and conform to the follow-
ing cable routing requirements:
•
Avoid small bend radii.
•
Avoid pinch points.
•
Avoid cable pulling or stretching.
•
Keep cables from rubbing against other compo-
nents or machinery.
•
If a lot of robot wrist motion is required, leave
sufficient cable length to allow for the motion,
avoiding any cable droops that may interfere
with the machinery or substrate.
•
Cable ties should only be used to loosely bundle
hoses together. Do not tighten cable ties to the
point where cable movement is restricted.
5.
Connect the operation cable to the fluid module
junction box.
6.
Check the connections to ensure the cable is con-
nected correctly.
F
IG
. 9
B
B
PrecisionFlo LT
Control Unit
*Operations Cable
Automation I/O
Automation I/O
Controller
*Available in
25’, 60’, or 125’
lengths of:
F
IG
. 10
CAUTION
Always make connections to the control assembly with
the power off.
13
17
Control Unit - Top View
Содержание 234129