Operation

Pressure Relief Procedure

Starting and Operating the Pump

This pump is designed to be used with a Graco Foam-Cat 
Sprayer. If you have purchased such a sprayer, complete 
warning and operating instructions are contained in the 
manual (307541 or 307542) which accompanied the 
sprayer. If you have misplaced these manuals, obtain 
additional copies by contacting your Graco distributor. 

In general operation, when the pump is used for transfer 
and supply operations with no dispensing valve, the pump 
will run whenever air is supplied.

Normally, the Feed Pump air valve is opened before any 
other equipment in the spray system is turned on. This is 
so fluid can be supplied to the components immediately. 
For shutdown, disconnect the air line coupler (13). See Fig  
4.

Never let the pump run when the drum is empty. A dry 
pump can quickly accelerate to a high speed and damage 
itself. If the pump is running too fast, stop it immediately 
and check and refill the material supply, or flush the pump 
with a compatible solvent if you stop spraying for the day. 
Always prime the entire system with fluid to remove any air 
pumped into the system. Refer to Manual 307541 or 
307542. Don’t let the material harden in the pump.

Feed Pump Kit

Refer to the operation instructions on page 2 of manual 
307548, which was supplied with the Air Dryer, and the 
above instructions for operating the Feed Pumps.

Changing Drums

1. Disconnect the hose coupler (N) from the Air Dryer 

drum fittings (H). See Fig 3.

2. Leave the ball valve (K) open for a few minutes to 

release the air pressure in the drum, then close the 
valves.

3. Remove the pump and the drum fittings from the 

drum cover and install them in the new drum of 
material.

4. Repeat this procedure for the other material.

 

WARNING

PRESSURIZED EQUIPMENT HAZARD

The system pressure must be manually relieved to 
prevent the system from starting or spraying 
accidentally. To reduce the risk of an injury from 
accidental spray from the gun, splashing fluid, or moving 
parts, follow the 

Pressure Relief Procedure

 whenever 

you:

are instructed to relieve the pressure,

 have an air supply interruption,

 stop spraying,

 check or service any of the system equipment,

 or install or clean the spray nozzle.

 

CAUTION

To avoid crossing material when changing drums, 
complete the changing of one type of material before 
starting the other.

Содержание 217-381

Страница 1: ...bar Maximum Material Working Pressure Model No 226946 Series B Includes airtight bung adapter Feed Pump Kit 217381 Includes two Model 226946 Feed Pumps air dryer and air and fluid hoses II 1 2 G T6 IT...

Страница 2: ...atible with the equipment wetted parts Refer to the Technical Data section of all equipment manuals Read the fluid and solvent manufacturer s warnings Do not use hoses to pull equipment Route hoses aw...

Страница 3: ...fer to Grounding on page 5 If there is any static sparking or you feel an electric shock while using this equipment stop pumping immediately Do not use the equipment until you identify and correct the...

Страница 4: ...abel RES or ISO to identify the type of material being pumped 4 Install an air regulator in the feed pump air inlet to control pump speed To install remove the air valve 8 and use suitable adapters fo...

Страница 5: ...filter and fill the bowl with the desiccant provided Reassemble 4 Install the drum fittings H in the 3 4 in vent port of the proper drum CAUTION Be sure all hose connections in your polyurethane foam...

Страница 6: ...fluid hose between the 3 4 npt f fluid outlet of the ISO feed pump and the 3 4 npt f inlet of the corresponding displacement pump Repeat for the RES pumps M 05218 FIG 3 KEY A Air Line B Air Line Filte...

Страница 7: ...e the entire system with fluid to remove any air pumped into the system Refer to Manual 307541 or 307542 Don t let the material harden in the pump Feed Pump Kit Refer to the operation instructions on...

Страница 8: ...brication turn off the air put about 15 drops of lightweight motor oil in the air inlet 7 reconnect the hose and turn on the air See Fig 4 1 Open the air valve 8 or regulator to start the pump Allow t...

Страница 9: ...ure closed or clogged air valves Check valves increase pressure Clogged material hose or valve Clear obstruction Worn or damaged valves or seals Service pump Pump operates but output is low on both st...

Страница 10: ...screw it from the outlet housing Pull the cylinder down then loosen the lower nut 19 Unscrew the piston housing 33 Clean and inspect all parts Replace worn or damaged parts Screw the connecting rod al...

Страница 11: ...307552 11 Service 28 21 32 22 24 18 38 39 40 41 25 30 34 19 26 19 33 29 23 31 27 18 35 36 05221 FIG 7 Torque to 31 N m 23 ft lb Torque to 33 N m 24 ft lb Lips face down...

Страница 12: ...12 307552 Parts Drawing 10 11 9 12 14 13 7 8 4 3 15 17 28 21 32 22 24 18 38 39 40 41 25 30 34 19 26 19 33 29 23 31 27 18 35 36 37 03768 05221 03768C 5...

Страница 13: ...LAND female packing PTFE 1 22 172385 GLAND male packing sst 1 23 172393 WASHER SST 1 24 178542 HOUSING outlet 1 25 172416 CYLINDER 1 26 177150 ROD connecting 1 27 177151 PISTON pump 1 28 177152 NUT pa...

Страница 14: ..._____________________________________________________________ ___________________________________________________________________________________________ ______________________________________________...

Страница 15: ...pm Fluid Outlet 3 4 npt f Air Inlet 1 4 npt f Fluid Inlet 1 1 2 npt f Wetted Parts Carbon steel 300 series stainless steel Leather Cadmium plated ductile iron Chrome and zinc plated steel PTFE Polyeth...

Страница 16: ...emedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury t...

Отзывы: