![Graco 17H466 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/graco/17h466/17h466_repair-parts_2250894010.webp)
Grounding Procedure (For Flammable Materials Only)
10
3A3394E Repair - Parts
Grounding Procedure
(For Flammable Materials Only)
1. Position striper so that the tires are not on pavement.
2. Striper is shipped with a grounding clamp. Grounding
clamp must attach to grounded object (e.g. metal sign
post).
Pressure Relief Procedure
1. Perform
Grounding Procedure
if using flammable
materials.
2. Set pump valve(s) to
OFF
(250
SPS
has one pump
valve; 250
DC
has two pump valves). Turn engine
OFF
.
3. Turn pressure control to lowest setting. Trigger all guns
to relieve pressure.
4. Engage all gun trigger locks. Turn prime valve(s) down
(250
SPS
has one prime valve; 250
DC
has two prime
valves).
5. If you suspect the spray tip or hose is clogged or that
pressure has not been fully relieved:
a. VERY SLOWLY loosen the tip guard retaining nut
or the hose end coupling to relieve pressure gradu-
ally.
b. Loosen the nut or coupling completely.
c. Clear the obstruction in the hose or tip.
This equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.