Grounding Instructions
3A1775C
7
Grounding Instructions
Sprayer
must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for electrical current due to static build
up or in the event of a short circuit.
1. This sprayer requires 220-240 VAC, 50/60 Hz
10A circuit with a grounding receptacle. Never
use an outlet that is not grounded.
2. Do not use sprayer if electrical cord has dam-
aged ground prong.
3. Do not use an extension cord with damaged
ground plug.
Recommended extension cords:
•
15 m (49.2 ft) 1.0 mm
2
•
30 m (98.4 ft) 1.5 mm
2
•
50 m (164.0 ft) 2.5 mm
2
4. Smaller gauge or longer extension cords may
reduce sprayer performance.
Thermal Overload
Motor has a thermal overload switch to shut itself
down if overheated. If unit overheats, allow approx-
imately 45 minutes for unit to cool. Once cool,
switch will close and unit will restart.
ti7529b
ti7528a
To reduce risk of injury from motor starting
unexpectedly when it cools, always turn power
switch OFF if motor shuts down.