Graco 16J750 Скачать руководство пользователя страница 20

Maintenance 

20

3A1775C

Maintenance

Caring for Sprayer

Clean sprayer and accessories thoroughly after 
each use. 

Do not cover vent holes or shroud while spraying.

Gun Fluid Filter

Clean gun fluid filter with compatible solvent and 
brush every time you flush system. Replace when 
damaged.

Paint Hoses

Check hose for damage every time you spray. Do 
not attempt to clean or repair hose if hose jacket or 
fittings are damaged. Do not use hoses shorter 
than 7.5 m 
(25 ft).

Tips 

Always clean tips with compatible solvent 
and brush after spraying.

Tip life: 57 liters (15 gallons) - 227 liters (60 
gallons)*

Do not spray with worn tip.

Pump Check Valves

Storing in water, inadequate flushing or 
ingested debris can cause either of the two 
check valves to malfunction.

If pump does not prime after 30 seconds, 
try to loosen check balls by pushing pump 
priming button or by tapping the inlet valve 
with a small wrench as the sprayer is strok-
ing.

NOTE:

 Excessive shock will fracture or cause 

other damage to pump.

NOTE:

 To verify inlet valve ball is sticking, 

unscrew valves from pump and check them. 

If sprayer continues to cycle (motor and pump 
run) after you release gun trigger, pump valves 
may be obstructed or worn. Valve repair kits 
are available from Graco/M

AGNUM

 authorized 

service centers.

Pump

When pump wears, paint will begin to leak down 
outside of pump. Replace pump at first sign of leak-
ing or additional damage could occur.
Pump repair kits are available from Graco/M

AGNUM

 

authorized service centers.

NOTICE

Openings in shroud provide air for cooling 
mechanical parts and electronics inside. If water 
gets in these openings sprayer could malfunction 
or be permanently damaged.

ti15970a

ti15972a

Содержание 16J750

Страница 1: ...25 ft hose Magnum X7 16J751 Series A Maximum Working Pressure 207 bar 21 MPa 3000 PSI Includes 1 17 lpm 0 31 gpm cart mount sprayer SG3 gun Manual 312830 0 635 cm 1 4 in x 15 m 50 ft hose Important Sa...

Страница 2: ...Install Tip and Guard on Gun 13 Spraying Techniques 13 Getting Started 13 Unclogging Spray Tip 14 Triggering Gun 14 Aiming Gun 14 Selecting the Right Tip 15 Tip Hole Size 15 Tip Number 16 Cleanup 17 C...

Страница 3: ...ug is able to result in a risk of electric shock Check with a qualified electrician or serviceman when the grounding instructions are not completely understood or when in doubt as to whether the produ...

Страница 4: ...hey are antistatic or conductive Connect to a grounded outlet and use grounded extensions cords Do not use a 3 to 2 adapter Do not use a paint or a solvent containing halogenated hydrocarbons Keep spr...

Страница 5: ...e lowest rated system component See Technical Data in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Data in all equipment manuals Read flu...

Страница 6: ...an cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read MSDSs to know the specific hazards of the fluids you are using Store hazardous fluid in approved container...

Страница 7: ...trical cord has dam aged ground prong 3 Do not use an extension cord with damaged ground plug Recommended extension cords 15 m 49 2 ft 1 0 mm2 30 m 98 4 ft 1 5 mm2 50 m 164 0 ft 2 5 mm2 4 Smaller gaug...

Страница 8: ...ower switch C Pressure control knob D Pump fluid outlet fitting G Suction Tube H Prime tube with diffuser J Prime Spray valve control K Fluid inlet connection and inlet valve L Inlet screen M Paint ho...

Страница 9: ...ssure control knob D Pump fluid outlet fitting G Suction Tube H Prime tube with diffuser J Prime Spray valve control K Fluid inlet connection and inlet valve L Inlet screen M Paint hose P SG3 airless...

Страница 10: ...e in waste pail 3 Turn Prime Spray valve to PRIME 4 Turn pressure control knob left minimum pres sure 5 Trigger gun into bucket to relieve pressure in hose Pressure Adjustment 1 Align arrow on sprayer...

Страница 11: ...2 Connect one end of grounded fluid hose to spray gun Use a wrench to tighten 3 Connect other end of hose to sprayer fluid out let fitting Use wrench to tighten 4 Turn pressure control knob left mini...

Страница 12: ...waste pail 5 Push pump priming button two times 6 Turn ON power switch Align arrow on sprayer and bucket symbol on pressure control knob 7 When paint without bubbles starts to come out of prime tube t...

Страница 13: ...to stop pumping when gun trigger is released Getting Started Hold gun 30 cm 12 in from surface and aim straight at surface Tilting gun to direct spray angle causes an uneven finish Flex wrist to keep...

Страница 14: ...ion Point the arrow shaped handle on the spray tip for ward to SPRAY and backward to UNCLOG obstructions Triggering Gun Pull trigger after starting stroke release trigger before end of stroke Gun must...

Страница 15: ...ole size smaller than the maximum will allow you to spray within rated flow capacity To prevent excessive wear spray at lowest pressure that atom izes paint NOTE If maximum pressure of sprayer is not...

Страница 16: ...8 10 in fan width and a 0 33 mm 0 013 in hole size order part no 286413 See manual 312830 for gun operating instructions and spray techniques Tip Part Number Fan Width 305 mm 12 in from surface Hole S...

Страница 17: ...l knob 5 While pump continues to stroke remove trigger lock Trigger gun into paint pail Turn Prime Spray valve to SPRAY Continue to trig ger gun until flushing fluid comes out of gun Release trigger N...

Страница 18: ...e Relief Procedure page 10 1 Engage gun trigger lock 2 Unscrew hose 3 Remove filter and clean it in compatible sol vent NOTE Do not soak entire gun in solvent Pro longed exposure to solvent can ruin p...

Страница 19: ...minimum pressure 4 Turn ON power switch 5 Align arrow on sprayer with roller symbol on pressure control knob 6 When storage fluid comes out of prime tube 5 10 seconds turn OFF power switch 7 Turn Pri...

Страница 20: ...nction If pump does not prime after 30 seconds try to loosen check balls by pushing pump priming button or by tapping the inlet valve with a small wrench as the sprayer is strok ing NOTE Excessive sho...

Страница 21: ...drain tube as necessary Return sprayer to Graco MAGNUM authorized service center if drain valve is clogged Power switch is on and sprayer is plugged in but pump does not cycle Pressure set at minimum...

Страница 22: ...raying Pump cycles but paint only dribbles or spurts when trigger is pulled Pressure is set too low Turn pressure control knob right to increase pressure Spray tip clogged Clean tip See Gun stops spra...

Страница 23: ...ressure setting or increase tip size Move sprayer to cooler location Building circuit breaker opens after sprayer operates for 5 10 minutes OR Building circuit breaker opens as soon as sprayer is plug...

Страница 24: ...Sprayer weight only 6 1 kg 13 3 lb 10 6 kg 23 3 lb Dimensions Length 36 0 cm 14 5 in 49 5 cm 19 5 in Width 31 5 cm 12 4 in 38 9 cm 15 3 in Height 45 5 cm 17 9 in 94 0 cm 37 0 in Wetted parts sprayer S...

Страница 25: ...Notes 3A1775C 25 Notes...

Страница 26: ...structures accessories equipment or materials not supplied by Graco or the improper design manufacture installation operation or maintenance of structures accessories equipment or materials not suppl...

Отзывы: