Cleanup
3A1775C
19
Filling Sprayer with Storage Fluid
1. Remove inlet strainer. Place suction tube in
storage fluid bottle and prime tube in waste
pail.
2. Turn Prime/Spray valve to PRIME.
3. Turn pressure control knob all the way left
(counterclockwise) to minimum pressure.
4. Turn ON power switch.
5. Align arrow on sprayer with roller symbol on
pressure control knob.
6. When storage fluid comes out of prime tube
(5-10 seconds) turn OFF power switch.
7. Turn Prime/Spray valve to SPRAY to keep stor-
age fluid in sprayer during storage.
Always pump storage fluid through pump system
after cleaning. Water left in sprayer will corrode
sprayer and damage pump.