E-Flo Plus Software Update
30
311596A
Advanced Options Screen
The advanced screen allows user changes to operating
parameters. This is only effective in the remote mode.
See F
Units of Measure
Select desired units (English or Metric). See F
Values on Run screen will change accordingly.
Trips
•
High Pressure Trip: Default is 300 psi. If measured
pressure is more than the set pressure, a high pres-
sure trip will occur. See T
20.09.
•
Low Pressure Trip: The low pressure trip is an
optional setting. To set, select the low pressure trip
box and input the desired value. If measured pres-
sure is less than the set pressure, a low pressure
trip will occur.
Flow Calibration
•
Lower Size: Select size of pump lowers (1000cc,
1500cc, or 2000cc).
•
Flow Ramp Rate: Default is 100 gpm. A higher rate
will prevent pressure from building up too rapidly,
which can cause nuisance high pressure trips.
Trend Timer
Trend timer is used for a timeline management for data
logging. Set desired trend time (1 to 5 seconds) or (1 to
5 minutes).
BPR Mode
Select Manual or Auto/Setup, as applicable. If
Auto/Setup is selected the BPR Timer Screen is dis-
played. See F
. 20.
CAM
•
CAM: CAM is the default. This setting utilizes the
E-Flo Plus cam profile which eliminates pressure
fluctuations by adjusting motor speed incrementally.
•
Constant Speed: Sets motor to a constant speed,
which negates the cam profile and may result in
pressure fluctuations.
Reset Batch Counter
Press to reset batch counter on Run screen.
Drive Status Messages
There are two groups of drive status messages:
•
Drive Health
•
Drive Warning Messages
An active status message will turn red. See T
page 32 for additional information.
Prime/Flush
Prime/flush allows system priming and flushing. Once
enabled, the pump will ramp up to the following flow
rates for two minutes.
•
2000 cc lower: 33.8 gpm (128.4 lpm)
•
1500 cc lower: 24.3 gpm (92.3 lpm)
•
1000 cc lower: 17.9 gpm (68.0 lpm)
BPR Production Flow Screen
Pressure must surpass the low pressure trip value
before the trip becomes active.
F
IG
. 18 BPR Production Flow Screen
BPR Production Flow Screen
is accessed from the options
menu in main screen