Positive Displacement Flowmeters
GM50 series instruction manual
GM50 Pulse • GM50 Standard LCD • G540 Deluxe LCD • From serial No. CXXXX
Страница 1: ...MS244G 0899 0001 Positive Displacement Flowmeters GM50 series instruction manual GM50 Pulse GM50 Standard LCD G540 Deluxe LCD From serial No CXXXX...
Страница 2: ...is available with either Standard Pulse Standard LC Display and Pulse Deluxe LC Display and Pulse PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE Before use confirm the fluid to be used is compatib...
Страница 3: ...6 The meter can be installed in any orientation as long as the meter shafts are in a horizontal plane Refer to Fig 2 for correct installation The register assembly may be orientated to suit the indiv...
Страница 4: ...the four large screws Item 30 on top of the LC Display Carefully separate the LC Display from the plastic housing and disconnect the wires from the Reed Switch Connections for PCB Terminals refer Fig...
Страница 5: ...urning either of the rotors If the rotors are not in mesh correctly or do not move freely remove one of the rotors and replace correctly at 90o to the other rotor Re check the operation of the rotors...
Страница 6: ...lay button until the bottom line displays Total 1 Locked Flow Rate The flow rate is the rate the fluid is flowing through the meter The flow rate setting can be found by pressing and releasing the dis...
Страница 7: ...c Magnets failed a Battery not connected properly b Battery flat c Faulty wiring connections d Faulty LC display e Faulty connection from LC display to Pulse PCB REMEDY a Dismantle meter clean rotors...
Страница 8: ...itch 5 1 MS201 HE PCB Hall Effect Sensor 5 1 MS201 R HE PCB 1 Reed Switch 1 Hall Effect Sensor 6 4 MS284S PCB Board Screws 7 6 MS243S Meter Cap Screws Standard 7 6 MS282S Meter Cap Screws Stainless St...
Страница 9: ...OTE Note Suitable for Intrinsic Use 33 1 MS307 Gasket MS275S Standard LC Display Complete 23 1 MS238 Mounting Adaptor Plate 24 4 MS203S Adaptor Screws 25 1 BS045 O Ring 26 1 MS205 LC Display 27 1 MS27...
Страница 10: ...to 350 4 to 92 33 to 300 9 to 79 0 5 1000 Centipoise As per flange rule 80 C 176 F Dual Reed Switches or Hall Effect Sensor or combination HE Sensor Reed Switch 6 68 13 3 or 25 28 50 34 Pulse with De...
Страница 11: ...ensions 178 mm 86 mm 188mm 18mm 55mm 137 mm 178 mm 55mm GM50 Pulse Meter Dimensions GM50 Pulse Meter with Standard LC Display GM50 Pulse Meter with Deluxe LC Display 240mm 152 mm 213mm 210mm 240mm 152...
Страница 12: ...make a claim against this warranty notice of claim must be given in writing to the company at its address below no later than 30 days after the expiration of the warranty period Such notice shall ide...