Owner's Manual

02 Series Electronic Flowmeter 
with Scaled Pulse Output

IMPORTANT NOTICE

This meter is not approved for use with flammable liquids. 

Do not use with liquids or chemicals that are not compat-

ible with the wetted materials found in the 

Specifications

 

section.
This meter is not legal for trade applications.
This meter is sensitive to electrical "noise" and may not op-

erate correctly if located near certain electrical equipment.

CALIBRATION

This meter has a permanent factory calibration for light 

viscosity fluids. If installed and used correctly, accuracies of 

no greater than ±5% will be obtained.

INSTALLATION

This meter may be installed in-line either horizontally or 

vertically, or at the end of the hose adjacent to the nozzle 

if present. For best accuracy, provide 10 inches of pipe 

upstream and 5 inches of pipe downstream. The use of pipe 

sealant or PTFE tape is acceptable. Review your application 

for suitability. Attach meter with arrow on outlet port pointed 

in the direction of flow.
For Aluminum Housings: Using a wrench, tighten meter at 

the ends.
For Nylon Housings: Hand tighten only. Avoid using metal 

connections, as this could damage the housing.

OPERATION

Batch and Cumulative Totals

This meter maintains two totals: 

Batch

 and 

Cumulative

The 

Batch

 total may be reset to measure flow during a 

single use. The 

Cumulative 

total provides continuous mea-

surement and may not be manually reset. The 

Batch

 total is 

labeled 

TTL1

. The 

Cumulative

 total is labeled 

TTL2

. When 

the 

Cumulative

 total reaches a maximum reading of 9999, 

it will automatically reset to zero. Press the DISPLAY button 

briefly to switch between 

Batch

 and 

Cumulative

 totals.

Activate the Meter

Turn the meter ON by starting fluid flow or briefly pressing 

the DISPLAY button. The meter will display the batch or 

cumulative total from last use.
Press DISPLAY briefly to display the batch total. Hold the 

DISPLAY button down for three seconds to reset that batch 

total to zero.
This meter is programmed to turn off automatically if not 

used for approximately one minute.
Scaled Output Pulse
For every whole unit (Gallon or Litre) that passes through the 

meter's Batch Total (TTL1), a single pulse is transmitted via 

the attach cable. The White wire is signal and the Black wire 

is common (GND) 

(See Specifications)

.

Note:

 Some interface devices may not have an internal pull-

up resistor. Use a minimum 820 ohms resistor if necessary 

(See Figure 1)

.

Batteries Included

Figure 1

CUSTOMER

INTERFACE

EQUIPMENT

5-30 VDC

 - PULSE

BLACK - COMMON

GND

INPUT

V+

PULL-UP

RESISTOR

WHITE

FIG. 1