Owner’s Manual for

01N31GM-U Electronic Flowmeter

Rev. -  920862-01

09/09

5252 East 36th Street North

Wichita, KS USA  67220-3205

TEL: 316-686-7361

FAX: 316-686-6746

IMPORTANT NOTICE

 

Use this meter with water, DEF or similar fluids. 

Do not use with flammable liquids, fuels or chemicals 

that are not compatible with the wetted materials 

found in the Specifications section.

 

This meter is not legal for trade applications.

 

The meter is sensitive to electrical “noise” and 

may  not  operate  correctly  if  located  near  some 

electrical equipment.

CALIBRATION

 

This meter has a permanent factory calibration 

for light viscosity fluids. If installed and used cor-

rectly, inaccuracies of no great er than ±5% will be 

obtained.

INSTALLATION

 

This meter may be installed in-line either horizon-

tally or vertically or at the end of the hose adjacent to 

the nozzle, if present. Installation to metal connections 

is not recommended.

 

The use of pipe sealant or PTFE tape is accept-

able. Review your application for suitability.

 

Hand tighten the meter at the housing ends. Do 

not use a wrench or similar tools to tighten the meter 

housing. The plastic housing could be damaged.

Batteries included.

OPERATION

Batch and Cumulative Totals

 

The meter maintains two totals. The batch total 

may be reset to measure flow during a single use. 

The cumulative total provides continuous measure-

ment and may not be manually reset. The batch total 

is labeled as TTL1. The cumulative total is labeled 

TTL2.

 

When the cumulative total reaches a maximum 

reading of 9999, it will automatically reset to zero.

 

Press  the  DISPLAY  button  briefly  to  switch 

between the batch and cumulative total.

Activate the Meter

 

Turn the meter ON by starting water flow or briefly 

pressing the DISPLAY button. The meter will display 

the batch or cumulative total from last use.

 

Press DISPLAY briefly to display the batch total. 

Hold the DIS PLAY button down for three seconds 

to reset the batch total to zero.

 

The meter is programmed to turn off automatically 

if not used for about one minute.

MAINTENANCE

 

Proper handling and care will extend the life and 

service of the meter.

Turbine Rotor

 

The meter is virtually maintenance-free. However, 

it is important the rotor moves freely. Keep the meter 

clean and free of contaminants. 

 

Remove any debris or deposits from the rotor 

using a soft brush or small probe. Be careful not to 

damage the turbine rotor or supports.

Blowing compressed air through the turbine 

assembly could damage the rotor.

CAUTION