![Gotting HG G-98830 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/gotting/hg-g-98830/hg-g-98830_operating-manual_2247547053.webp)
Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
53
Configuration of the System via the Service Interface – Chapter 10
changes made, you may then have to use a different baud rate or a different text
document to call up the monitor (see 10.1 „Starting the Monitor Program“ on page
48).
To switch from the main menu to the
(S)erial Output
menu:
Press the key
.
The following screen will be displayed:
Figure 24
Menu: (S)erial Output
Switch baud rate
With the parameter (B)audrate you define the speed with which the telegrams are
transmitted via the serial interface. The baud rate must be set the same for all serial
devices.
Selection:
19200 Baud
38400 Baud
To switch the baud rate:
Press the key
and enter the desired value.
Setting the procedure for telegram transmission
The parameter
(P)rocedure
is used to set the procedure for the monitor program at
the antenna:
Selection:
Monitor only (Service/Configuration)
3964R (Data)
transparent (Data)
For setting the procedure for the data transmission:
Press the key
and enter the desired value.
S:0006 D:+006 D_X:+32767 D_Y:+32767 Code: 00000001 Read: 42:
N: 0
Frx[/Hz]:66800 Ftx[/Hz]:127990
U[/mV]:24000 I[/mA]: 260 T[Grd.C]:+33 E: 0000 Noise 0
(B)audrate: 38400
(P)rocedure 3964R
(O)rder of Data Transfer (0= HiByte first): 0
(T)elegram Content Mask [0..1FFF]: 00001fff
(D)isplay Telegram Content
(C)har-Delaytime [1..220ms]: 220
(A)ck-Delaytime (3964R) [1.1680ms]: 1680
Co(n)tinous Telegrams 0
(S)erial Data Period [4.500mS]: 8
(F)reeze Values for n Telegrams:[0..10]: 0
(Q)uit Menue