Device Description HG G-7335xZA | English, Revision 05 | Date: 19.02.2020
36
Chapter 8 – CAN Interface (HG G-73350)
8.5.3 Standard device profile
When applying “Restore All“ the node ID is set to 1 and the baud rate to 125 Kbaud.
8.5.4 CANopen Object Dictionary
8.5.4.1 Device Type
8.5.4.2 Error Register
Displays always 0 (no error)
0x2002
0
RO
Number of Parameter
1
RW
Node Baudrate
C
2
RW
Node ID
C
3
RW
Node Config
C
Table 27
CAN: overview object directory, standardized device profile from 0x6000 on
Standard device profile from 0x6000 on
Index
Subindex
Access
Content
0x6000
0
RO
Number of 8 Bit Digital Inputs
1
RO
System status
0x6401
0
RO
Number of 16 Bit analog Inputs
1
RO
Analog Input Us1
2
RO
Analog Input Ud1
3
RO
Analog Input Us2
4
RO
Analog Input Ud2
5
RO
X1 [mm]
6
RO
X2 [mm]
Table 28
CAN: Device Type
Index
Sub Index Name
Format
Attr. Map Default
Meaning
0x1000 00
Device Type
Unsigned 32 RO
No
0x00050191 Digital/analog
inputs - DS 401
Table 29
CAN: Error Register
Index
Sub Index Name
Format
Attr. Map Default
Meaning
0x1001 00
Error Register Unsigned 8
RO
No
0x00
Error register
Table 26
CAN: overview of object directory, manufacture specific entries from 0x2000 on
(part 2 of 2)
Manufacturer entries from 0x2000 on
Index
Subindex
Access
Content
EEProm