Device Description HG G-71912-A | English, Revision 03 | Date: 28.03.2018
28
Chapter 5 – Components and Operation
•
Node parameter
*) Coding of baud rates
**) After changing these points the values has to be saved with <save all> and a node reset
has to be proceeded
Bit Value Name
Meaning
0x0004
HILO
Byte order for variable ii TxPDO_1: "High Byte first" if set
0x0020
AUTOSTART
CANopen® starts in mode "operational"
0x0200
POSI
0: only one POSI pulse possible in field, 1: pulse at each
crossing
0x2000
POSI_TRANSP 0: POSI pulse independent from decoding 1: POSI pulse only
after decoding
Table 29
Coding of the system configuration
Index
Sub Index
Name
Typ
Attr.
Map
Default
Bedeutung
0x2001
00
number of parameter
Unsigned 8
RO
No
0x02
Number of sub
indexes
01
Node Baudrate
Unsigned 8
RW
No
0x04
125 Kbaud
*)
§
02
Node ID
Unsigned 8
RW
No
0x01
Node address 1
**)
Table 30
Explanations - Node Parameter
Entered/read-out value
Baud rate / kBaud
8
10
7
20
6
50
4 (Default)
125
3
250
2
500
0
1000
Table 31
Coding of baud rates