Commissioning
English, Revision 02, Date: 12.07.2011
10
3
Commissioning
NOTE!
Check the operating voltage before connecting! Although the
RS 232 interface reacts largely insensitive to interferences, the
cable should not be located directly beside power supply
cables.
Connect all necessary cables. For the next commissioning steps connect a laptop with
the antenna. Then start the monitor program as described in section 5.2 on page 35.
1.
Move the transponder below the antenna
In the status line the voltage S has to rise significantly. The code has to be
detected immediately and the number of readings has to be counted up to 255
constantly. When the transponder crosses the center axis of the antenna in driv-
ing direction, a positioning pulse has to be generated.
2.
Remove the transponder from below the antenna
If there is no transponder in the field, the voltage S has to fall to extremely small
values. The code display and an possible display of the number of readings
remain. If that is not the case, interferences in a frequency range of 64 kHz are
induced.If no errors occurred, the monitor program can be closed. Remember
to save possibly altered values. After changing certain parameters, a system
reset is required (turning off and on the antenna). This procedure is explained in
the corresponding chapter of the monitor program (see chapter 5.2 "System
Monitor" on page 35).
3.
Now proceed an one-time reference transponder setup by transmitting the cor-
responding serial command (see table 4.3.2.1.2 on page 20) or by using the
corresponding submenu in the monitor program (see table 5.2.1 on page 35).
NOTE!
This command may only be carried out once during the commis-
sioning, as otherwise changes in the accuracy of the antenna
remain undiscovered, as they are included in the reference val-
ues each time a setup of the reference transponders is pro-
ceeded!
The new reference values, found during the reference transponder setup (sum. and
difference voltage), are saved automatically to the parameter E
2
PROM when applying
the serial command.
4.
Now, it is recommended to protocol a complete drive. Depending on the
antenna version there are different possibilities:
Parallel interface (in the interpreter version HG 71912YA)
Here, a logging is possible via a serial interface (see chapter 5.2.2.9 on page 45).
CAN-Bus (in the interpreter version HG71912ZA, XA)
Here, a logging is possible via a serial interface (see chapter 5.2.2.9 on page 45).