Mounting and Setup
English, Revision 03, Date: 07.02.2012
17
NOTE!
If several antennas are applied within one installation they have
to be mounted in a
minimum distance of 1500 mm
to one
another to guarantee a smooth production flow.
All indications refer to the position of the ferrite rod in the antenna:
Figure 7
Nominal reading distance / position of the antenna ferrite rod
3.3.2
Connection
Connection cables are not part of the scope of supply. The needed kind of cables are
commercially obtainable at many manufacturers (e. g. Binder 79-3444-32-05 M12 line
2 m PUR 5 x 025).
Accessory parts as an elbow jack with different cable lengths available (standard
2 m).
If a high interference level is expected shielded wires ought to be used.
3.4
Maintenance
The system is largely maintenance- free. Generally maintenance is restricted to
-
Visual examination of the antenna
-
Inspection if all screws, cables and plugs are properly fixed.
Direction of Travel
mounting level
m
oun
ti
n
g
le
ve
l
metal-free
metal-free
re
ading
Position of
the ferrite rod
area
area
distance