106
MDE-LEDI-NETWORK-IN-4065V1.0
1. PROCEDURE TO fOLLOW TO CHaNGE THE BaTTERY
Tools : Screw Driver
►
Gorgy Timing reference : BaT1728S
►
Life period : 5 years
►
BaTTERY CHECKING
Connect the product to the 230VAC during one hour.
►
Remove the power supply.
►
Open the product with the screw driver, the battery is located between the power
►
supply card and the display card
Disconnect the old battery with the screw driver.
►
Check the voltage, if the voltage is
►
less than 7V, the battery is on failure
.
Connect the new battery with the screw driver.
►
aPPENDIx
D – MaINTENaNCE
Display
Output 1
Output 2
Output N
Battery
Synch. input
…
Power
Supply
Содержание LEDI Network IN
Страница 1: ...MDE LEDI NETWORK IN 4065V1 0 LEDI NETWORK in MODE D EMPLOI page 3 USER GUIDE page 49...
Страница 38: ...38 MDE LEDI NETWORK IN 4065V1 0 Le connecteur DB9 a le format suivant 5 4 3 2 1 9 8 7 6 GND TXD TX TX...
Страница 40: ...40 MDE LEDI NETWORK IN 4065V1 0 2 Carte type B AFNOR IRIG B NFS87500 2 1 Format de la trame...
Страница 41: ...41 MDE LEDI NETWORK IN 4065V1 0 Annexe B Format du code de sortie 2 2 Encodage des bits FRANCAIS...
Страница 47: ...47 MDE LEDI NETWORK IN 4065V1 0 NOTES FRANCAIS...
Страница 49: ...49 MDE LEDI NETWORK IN 4065V1 0 USER GUIDE LEDI Network in ENGLISH...
Страница 115: ...115 MDE LEDI NETWORK IN 4065V1 0 NOTES ENGLISH...