Maintenance level access
• By pressing field no.
4
, you can activate the maintenance mode (
Figure 10
).
• A display menu with an inscription “code” in the filed
CLOCK
appears. Enter the maintenance code (fields FN1, FN2, FN3, FN4,
FN5 in FN6 for numbers 1, 2, 3, 4, 5, 6).
• If you do not press any field for 10 s, the programme returns to the start menu.
• If the code is incorrect, the programme returns to previous operation.
• If the code is correct, the first parameter appears on the display. The number on the right is the serial number of the parameter
and the field on the left is intended for its value.
• The first parameter
:00
is a version of a software code and serves information purposes only.
• By pressing the right number (Field
CLOCK
in
Figure 14
) you proceed to the next parameter.
Installation level (code 1166)
After the first code entry for the installation level the programme allows access to the following parameters:
•
:00
programme code
• :
21
fan speed 20, 25, …, 95, 100
• :
27
low temperature mode YES/NO
• :
34
PV function YES/NO
• :
40
ventilation YES/NO
Fan speed settings (parameter: 21)
Select the parameter
:21
and set the fan speed by pressing (
+
) or (
-
) (20% - 100%). See the numerical value settings on the left side
in field
5
. When the fan speed is set, you can save the changes by waiting a few moments or by pressing no.
4
.
Setting low-temperature mode (parameter :27)
Select the parameter
:27
and change the temperature by pressing (
+
) or (
-
). The temperatures depend on the model of the heat
pump.
The low-temperature mode is possible only if the heat pump model enables this function!****
The settings are shown on the left side (in the field TEMP):
Yes
– heat pump model ZGNT, operation mode of the heat pump (higher than -7°C), the system contains a 4-way valve.
No
– heat pump model Z, ZG, operation mode of the heat pump (higher than 7°C), the system does not contain a 4-way valve.
PV function activation (photovoltaics) (parameter :34)
Yes
– activated
No
– deactivated
Fan activation (parameter :40)
Yes
– activated
No
– deactivated
Anti-legionella function
• Works only when the heat pump is switched on. When activated, symbol no.
17
is displayed.
• Automatic activation: every 2 weeks of operation of the heat pump.
• Anti-legionella programme can be activated manually by pressing field no.
15
.
Figure 14:
Fields display
C
o
FN1
FN4
FN2
TEMP
CLOCK
FN5
FN3
MINUS
STBY
PLUS
FN6
33
EN
542916