Goodwe SDT SERIES Скачать руководство пользователя страница 1

340-00352-00-PC

Note: The information above is subject to change without prior motice, details refer to www.goodwe.com

SDT SERIES USER MANUAL

SOLAR INVERTER

GoodWe (Germany)

Fürstenrieder Str. 279a 81377 München, Germany
T: +49 897449 421 83570-170 (service)
[email protected]
[email protected]

GoodWe (Brazil)

Rua Abelardo 45, Recife/PE, 52050-310
T: +55 81 991239286
[email protected]
[email protected]

GoodWe (Netherlands)

Franciscusdreef 42C, 3565AC Utrecht, the Netherlands
T: +31 (0) 30 737 1140
[email protected]
[email protected]

GoodWe (UK)

6 Dunhams Court, Dunhams Lane, Letchworth
Garden City, SG6 1WB UK
T:+ 44 (0) 333 358 3184
[email protected]  /  [email protected]

GoodWe (India)

1202, G-Square Business Park, Sector 30A, Opp. Sanpada
Railway Stn., Vashi, Navi Mumbai- 400703
T: +91 (0) 2249746788
[email protected]  /  [email protected]

GoodWe (Italy)

Via Cesare Braico 61, 72100 Brindisi, Italy
T: +39 338 879 38 81; +39 831 162 35 52
[email protected] (sales)
[email protected]; [email protected] (service)

GoodWe (Turkey)

Adalet Mah. Megapol Tower K: 9 No: 110 Bayrakl

ı

 - Izmir

T: +90 (232) 935 68 18
[email protected]
[email protected]

GoodWe (Australia)

Level 14, 380 St. Kilda Road, Melbourne,
Victoria, 3004, Australia
T: +61 (0) 3 9918 3905
[email protected]  /  [email protected]

GoodWe (Mexico)

Oswaldo Sanchez Norte 3615, Col. Hidalgo, Monterrey,
Nuevo Leon, Mexico, C.P. 64290
T: +52 1 81 2871 2871
[email protected] / [email protected]

GoodWe (Korea)

8F Invest Korea Plaza, 7 Heoleung-ro
Seocho-gu Seoul Korea (06792)
T: 82 (2) 3497 1066
[email protected] / [email protected]

GoodWe (China)

No. 90 Zijin Rd., New District, Suzhou, 215011, China
T: +86 (0) 512 6958 2201
[email protected] (sales)
[email protected] (service)

SEMS Portal APP

SolarGo APP

SEMS Portal website

www.semsportal.com

LinkedIn

Sitio web ofical

Содержание SDT SERIES

Страница 1: ...46788 sales goodwe com service in goodwe com GoodWe Italy Via Cesare Braico 61 72100 Brindisi Italy T 39 338 879 38 81 39 831 162 35 52 valter pische goodwe com sales operazioni topsenergy com goodwe...

Страница 2: ...Electrical Connection 11 11 12 16 16 16 4 System Operation 4 1 Indicator Lights 4 2 User Interface and Use of the Display 4 3 Error message 4 4 Wi Fi Reset Wi Fi Reload 4 5 Special Adjustable Setpoin...

Страница 3: ...ed When exposed to sunlight the PV array will generate dangerous high DC voltage Please operate according to our instructions or it will result in danger to life PV modules should have an IEC61730 cla...

Страница 4: ...on bolts in the accessories bag 3 Hold the inverter by the side groove as Figure 3 3 2 2 4 Install the inverter on the wall mounted bracket Please refer to Figure 3 3 2 3 For dissipation of heat and c...

Страница 5: ...ue line conductor shall be black or brown preferred protective earth bonding line shall be yellow green Fix moment 0 6N m the connector of AC cable to the corresponding terminals 3 4 2 AC circuit brea...

Страница 6: ...t buckle can not crimping the wire Negative connector Positive connector DEVALAN SERIES MC4 SERIES AMPHENOL SERIES QC4 10 SERIES There are four types of DC connectors DEVALAN SUNCLIX MC4 AMPHENDL H4 a...

Страница 7: ...ator LED on the front cover will light up For none wi inverter the buzzer in inverter will keep ringing 1 minute and ring again after half an hour unless the fault is resolved This function is only av...

Страница 8: ...e switching fault occurrence or key operation In all levels of menu if no action is taken for 20 seconds the backlight of the LCD display will be switched o and the display will automatically revert t...

Страница 9: ...t of LCD will power o and screen return to the rst level menu If you change the Language the LCD screen will show Setting after 10 seconds then show 14 13 50Hz GridDefault Lock No Error UtilityLoss 19...

Страница 10: ...ed to enter a password before setting up power limit The default password is 1111 only for Australian security regulations Set OK or Set Fail Set time From the rst level Set language menu short press...

Страница 11: ...n 3 If the problem still exists please call the local service o ce 1 Disconnect DC switch take o the AC connector and then measure the voltage between line and neutral in connector Check if it conform...

Страница 12: ...r rstly and then disconnect DC breaker Wait 5 minutes until the residual voltage has been drained 1 Please make sure the voltage of PV string will not exceed the Max DC voltage 20 19 GW12KT DT 18000 1...

Отзывы: