User Manual
V1.0-2022-10-30
Grid-Tied PV Inverter
MS Series
0.7-3.3kW
Страница 1: ...User Manual V1 0 2022 10 30 Grid Tied PV Inverter MS Series 0 7 3 3kW...
Страница 2: ...ptions here are for guidance only and other GOODWE trademarks are trademarks of GoodWe Technologies Co Ltd All other trademarks or registered trademarks mentioned in this manual are owned by GoodWe Te...
Страница 3: ...allation 4 2 5 Personal Requirements 5 3 Product Introduction 6 3 1 Application Scenarios 6 3 2 Circuit Diagram 6 3 3 Supported Grid Types 6 3 4 Appearance 7 3 4 1 Parts 7 3 4 2 Dimensions 8 3 4 3 Ind...
Страница 4: ...le 28 6 5 7 Installing the Communication Module optional 29 6 5 8 Connecting the USB RS485 Cable 29 7 Equipment Commissioning 30 7 1 Check Before Power ON 30 7 2 Power On 30 8 System Commissioning 31...
Страница 5: ...0 XS B11 3000W 220V 1 About This Manual This manual describes the product information installation electrical connection commissioning troubleshooting and maintenance Read through this manual before i...
Страница 6: ...defined as follows DANGER Indicates a high level hazard that if not avoided will result in death or serious injury WARNING Indicates a medium level hazard that if not avoided could result in death or...
Страница 7: ...with local standards and safety regulations Use insulating tools and wear personal protective equipment when operating the equipment to ensure personal safety Wear anti static gloves cloths and wrist...
Страница 8: ...ltage and frequency at the connection point meet the inverter grid connection requirements Additional protective devices like circuit breakers or fuses are recommended on the AC side Specification of...
Страница 9: ...irements NOTICE Personnel who install or maintain the equipment must be strictly trained learn about safety precautions and correct operations Only qualified professionals or trained personnel are all...
Страница 10: ...nerated by the PV module into AC power for loads or the grid The intended use of the inverter is as follows DC Switch Mains bridge relay Mains relay I P Filter surge Voltage protection PV insulation c...
Страница 11: ...nication Module Port Connect a communication module like Bluetooth WiFi LAN 4G etc The module type may differ depending on actual needs Connect the USB RS485 cable in Brazil Update the software versio...
Страница 12: ...k Used to cool the inverter 11 Mounting Plate Used to install the inverter Indicator Status Description ON WiFi is connected active BLINK 1 WiFi system is resetting BLINK 2 WiFi not connect to the rou...
Страница 13: ...10 30 03 Product Introduction 3 4 4 Nameplate The nameplate is for reference only GW trademark product type and product model Technical parameters Safety symbols and certification marks Contact inform...
Страница 14: ...the product and contact the supplier 3 Check the deliverables for correct model complete contents and intact appearance Contact the supplier as soon as possible if any damage is found Inverter x 1 Mou...
Страница 15: ...age or throw the desiccant away 2 Store the equipment in a clean place Make sure the temperature and humidity are appropriate and no condensation 3 The height and direction of the stacking inverters s...
Страница 16: ...in a place that is easy to touch especially within children s reach High temperature exists when the equipment is working Do not touch the surface to avoid burning 8 Install the equipment at a height...
Страница 17: ...de down forward tilt back forward tilt or horizontally Mounting Support Requirements The mounting support shall be nonflammable and fireproof Make sure that the support surface is solid enough to bear...
Страница 18: ...the equipment Use other auxiliary tools on site if necessary Installation Tool Requirements Torque wrench Cable tie Multimeter Marker Level Heat shrink tube Rubber hammer Goggles Safety shoes Safety g...
Страница 19: ...Keep balance to avoid falling down when moving the equipment Step 1 Put the mounting plate on the wall or the support horizontally and mark positions for drilling holes Step 2 Drill holes to a depth...
Страница 20: ...e specifications shall meet local laws and regulations DANGER Disconnect the DC switch and the AC output switch of the inverter to power off the inverter before any electrical connections Do not work...
Страница 21: ...e PV string to the inverter Otherwise the inverter may be damaged permanently or even cause fire and cause personal and property losses 1 Make sure that the max short circuit current and the max input...
Страница 22: ...vers when they are not to be used Otherwise the ingress protection rating will be influenced Step 1 Prepare DC cables Step 2 Crimp the crimp contacts Step 3 Disassemble the PV connectors Step 4 Make t...
Страница 23: ...trical Connection GW2500N XS GW3000N XS GW3KB XS GW2500 XS 11 GW3000 XS 11 GW3000 XS B11 600V Others 500V Click Click Devalan PV connector GW2500N XS GW3000N XS GW3KB XS GW2500 XS 11 GW3000 XS 11 GW30...
Страница 24: ...e AC circuit breaker for each inverter Multiple inverters cannot share one AC circuit breaker An AC circuit breaker shall be installed on the AC side to make sure that the inverter can safely disconne...
Страница 25: ...may be too hot to damage the inverter when the inverter is working Inverter model AC circuit breaker GW700 XS 300mA GW1000 XS GW1500 XS GW2000 XS GW2500 XS GW3000 XS GW2500N XS GW3000N XS GW3KB XS GW3...
Страница 26: ...22 User Manual V1 0 2022 10 30 06 Electrical Connection Click AC Connector 1 AC Connector 2 or AC Connector 1 Click Copper...
Страница 27: ...Electrical Connection AC Connector 2 Copper Click NOTICE Make sure that the cable is connected correctly and securely Clear the debris after completing the connection Seal the AC output terminal to en...
Страница 28: ...d parameters via LCD or SolarGo app to enable export power limit control or output power limit control CT90 6 5 2 Connecting the Communication Cable optional NOTICE DRED Demand response enabling devic...
Страница 29: ...ulations in Europe Related devices should be prepared by customers CT 1 CT 2 CT Realize the anti backfeed function by connecting the meter and the CT Contact the manufacturer to purchase the devices i...
Страница 30: ...26 User Manual V1 0 2022 10 30 06 Electrical Connection 6 5 4 Connecting the Remote Shutdown Cable No Function 4 Content 5 Content...
Страница 31: ...27 User Manual V1 0 2022 10 30 06 Electrical Connection 6 5 5 Connecting the CT Cable No Function 1 CT 2 CT...
Страница 32: ...28 User Manual V1 0 2022 10 30 06 Electrical Connection No Function 3 DRM1 5 4 DRM2 6 5 DRM3 7 6 DRM4 8 7 REFGEN 8 COM DRM0 6 5 6 Connecting the DRED Cable...
Страница 33: ...ule into the inverter to establish a connection between the inverter and the smartphone or web pages The communication module can be a Bluetooth module WiFi module LAN module GPRS moduel or 4G module...
Страница 34: ...ly and securely 3 Cable ties are intact routed properly and evenly 4 Unused ports and terminals are sealed 5 The voltage and frequency at the connection point meet the inverter grid connection require...
Страница 35: ...er OFF The inverter is not feeding power at the moment ON A fault has occurred OFF No fault Faulty Operating Power 8 2 Setting Inverter Parameters via LCD NOTICE Inverter software version shown in thi...
Страница 36: ...ess Short press Long press for 2s Long press for 2s Long press for 2s Long press for 2s Long press for 2s Long press for 2s Long press for 2s Long press for 2s Long press for 2s Long press for 2s Long...
Страница 37: ...tion Parameters Description Normal Home page Indicates the real time power of the inverter Long press for 2s to check the current safety code E Today Check the generated power of the system for that d...
Страница 38: ...fter restoring the factory settings PF Adjust Set the power factor of the inverter according to actual situation Time Interval Set Time Interval according to actual needs Shadow MPPT Enable the shadow...
Страница 39: ...Ftp EN Downloads User 20Manual GW_SolarGo_User 20Manual EN pdf to get the user manual SolarGo App SolarGo App User Manual Step 1 Contact the after sales service to obtain the upgrade package Step 2 S...
Страница 40: ...If the inverter cannot work anymore dispose of it according to the local disposal requirements for electrical equipment waste The inverter cannot be disposed of together with household waste 9 4 Trou...
Страница 41: ...will automatically restart within 5 minutes if the grid returns to normal 2 Make sure grid voltage conforms with the specification 3 Make sure neutral N wire and PE wire are connected well 4 Contact l...
Страница 42: ...ray voltage is lower than 250V please check configuration of inverter module 4 If voltage is higher than 250V please contact local office Others Wi Fi module fail to connect to network 1 If the Wi Fi...
Страница 43: ...ten consecutive times to make sure that it is working properly Once a year Electrical Connection Check whether the cables are securely connected Check whether the cables are broken or whether there i...
Страница 44: ...PT 1 1 1 1 Output Nominal Output Power W 700 1 000 1 500 2 000 Nominal Output Apparent Power VA 700 1 000 1 500 2 000 Max AC Active Power W 1 800 1 100 1 650 2 200 Max AC Apparent Power VA 2 800 1 100...
Страница 45: ...Operating Temperature Range 25 60 Relative Humidity 0 100 Max Operating Altitude m 3 4000 Cooling Method Natural Convection User Interface LED LCD Optional WLAN APP Communication WiFi LAN or RS485 Opt...
Страница 46: ...er VA 2 500 3 000 Max AC Active Power W 1 2 750 3 300 Max AC Apparent Power VA 2 2 750 3 300 Nominal Power at 40 W Only for Brazil 2 500 3 000 Max Power at 40 Including AC Overload W Only for Brazil 2...
Страница 47: ...4000 Cooling Method Natural Convection User Interface LED LCD Optional WLAN APP Communication WiFi LAN or RS485 Optional Communication Protocols Modbus RTU SunSpec Compliant Weight kg 5 8 Dimension W...
Страница 48: ...3 000 3 000 3 300 Nominal Output Apparent Power VA 2 500 3 000 3 000 3 300 Max AC Active Power W 1 2 750 3 300 3 300 3 300 Max AC Apparent Power VA 2 2 750 3 300 3 300 3 300 Nominal Power at 40 W Onl...
Страница 49: ...rating Temperature Range 25 60 Relative Humidity 0 100 Max Operating Altitude m 3 4000 Cooling Method Natural Convection User Interface LED LCD Optional WLAN APP Communication WiFi LAN or RS485 Option...
Страница 50: ...ax Backfeed Current to The Array A 0 0 0 0 Number of MPP Trackers 1 1 1 1 Number of Strings per MPPT 1 1 1 1 Output Nominal Output Power W 700 1000 1500 2000 Nominal Output Apparent Power VA 700 1000...
Страница 51: ...cy 97 2 97 2 97 3 97 5 European Efficiency 96 0 96 4 96 6 97 0 Protection PV Insulation Resistance Detection Integrated Residual Current Monitoring Integrated Anti islanding Protection Integrated AC O...
Страница 52: ...8 75 Max Backfeed Current to The Array A 0 0 0 Number of MPP Trackers 1 1 1 Cooling Method Natural Convection User Interface LED LCD WLAN APP Communication WiFi or LAN or RS485 Optional Weight kg 5 8...
Страница 53: ...tput Current A 12 14 3 14 3 Max Output Fault Current Peak and Duration A at 5ms 25 30 30 Inrush Current Peak and Duration A at 2 s 50 50 50 Nominal Output Current A 11 4 10 9 13 6 13 0 13 6 Power Fact...
Страница 54: ...er Off Optional Remote Shutdown Optional General Data Operating Temperature Range 25 60 Relative Humidity 0 100 Max Operating Altitude m 3 3000 Cooling Method Natural Convection User Interface LED LCD...
Страница 55: ...GoodWe Technologies Co Ltd No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com Contact Information Official Website...