RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

ATTENTION INSTALLING PERSONNEL

Prior to  installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings. During

installation or repair, caution is to be observed.

It is your responsibility to install the product safely and to educate the customer on its safe use.

Goodman Manufacturing Company, L.P.

5151 San Felipe, Suite 500, Houston, TX 77056

www.goodmanmfg.com

©

 2015-2016 Goodman Manufacturing Company, L.P.

I

NSTALLATION

 I

NSTRUCTIONS

F

OR

 S

ELF

-C

ONTAINED

 P

ACKAGE

H

EAT

 P

UMP

 U

NITS

GPH16 “M” SERIES

*NOTE:  Please contact your distributor or our

website for the applicable

Specification Sheets referred to in this manual.

These installation instructions  cover  the 

outdoor

installation of self contained package air conditioners
and heating units. See the Specification Sheets
applicable to your model for information regarding
accessories.

Affix this manual and Users Information Manual adjacent to the unit.

IOG-3013A

1/2016

Содержание GPH1624M41

Страница 1: ...Suite 500 Houston TX 77056 www goodmanmfg com 2015 2016 Goodman Manufacturing Company L P INSTALLATION INSTRUCTIONS FOR SELF CONTAINED PACKAGE HEAT PUMP UNITS GPH16 M SERIES NOTE Please contact your d...

Страница 2: ...RCULATING AIRAND FILTERS 7 AIR FLOW CONVERSION 7 DUCT WORK 7 FILTERS 7 PIPING 8 CONDENSATE DRAIN 8 WIRING 8 HIGH VOLTAGE WIRING 8 LOW VOLTAGE WIRING 9 INTERNAL WIRING 9 STARTUP ADJUSTMENTS AND CHECKS...

Страница 3: ...TE AIR VOLUME THROUGH INDOOR COIL 14 OUTSIDE AIR INTO RETURN DUCT 14 UNDERCHARGE 14 POOR TERMINATING SENSOR CONTACT 14 MALFUNCTIONING REVERSING VALVE THIS MAY BE DUE TO 14 APPENDIX 15 TROUBLESHOOTING...

Страница 4: ...ck the unit model number specifications electrical characteristics and accessories to determine if they are correct In the event an incorrect unit is shipped it must be returned to the supplier and mu...

Страница 5: ...l necessary internal electrical wiring The heat pump also includes a reversing valve solenoid defrost thermostat and control and loss of charge protection The system is factory evacuated charged and p...

Страница 6: ...cient structural strength to carry the weight of the unit s and snow or water loads as required by local codes Consult a structural engineer to determine the weight capabilities of the roof The unit m...

Страница 7: ...methods of Air Conditioning Contractors of America Manual D Residential or Manual Q Commercial All duct work exposed to the outdoors must include a weatherproof barrier and adequate insulation A duct...

Страница 8: ...isconnect near the unit Determine wire sizes and overcurrent protection from the unit nameplate ampacity and in accordance with the Minimum Filter Size or the N E C The wiring should never be sized sm...

Страница 9: ...CHECKS COOLING START UP PROCEDURES With power turned off at all disconnects 1 Turn thermostat system switch to COOL and fan switch to AUTO Next turn the temperature setting as high as it will go 2 In...

Страница 10: ...tc Set the thermostat at the appropriate setting for cooling and heating or automatic changeover for normal use NOTE The Cooling Start up Procedure is a recommended step as it serves as an system indi...

Страница 11: ...e heating capacity of the heat pump This phenomenon is a characteristic of a heat pump It is a good practice to provide supplementary heat for all heat pump installations in areas where the temperatur...

Страница 12: ...r air up to the maximum static pressure listed for the CFM required by the application i e home building etc In general 400 CFM per ton of cooling capacity is a rule of thumb Some applications dependi...

Страница 13: ...mid way between the compressor and the reversing valve NOTE The thermometer must be well insulated to prevent ambient influences 3 Allow the compressor to operate for about 10 additional minutes and m...

Страница 14: ...t pass through the indoor coil to prevent excessive discharge pressure and high pressure cut out OUTSIDE AIR INTO RETURN DUCT Do not introduce cold outside air into the return duct of a heat pump inst...

Страница 15: ...15 APPENDIX...

Страница 16: ...grounded or open winding open internal overload b Wait at least 2 hours for overload to reset If still open replace the com pressor c Low voltage connection c At com pressor term inals voltage m ust b...

Страница 17: ...312 321 326 332 348 353 360 Downshot Position Motor sp Volts Static Model 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 T1 230 CFM 722 672 574 509 Watts 60 74 80 89 T2 T3 230 CFM 1103 1038 978 922 806 731 676 6...

Страница 18: ...CFM 1745 1690 1615 1580 1530 1470 1420 1370 1310 Watts 425 435 440 465 468 476 488 498 500 Horizontal Position Motor sp Volts Static Model 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 T1 230 CFM 1167 1101 1045...

Страница 19: ...47 SUPPLY 1 3 8 A RETURN POWER WIRE ENTRANCE 4 1 8 2 1 8 6 16 16 5 B B CONTROL WIRE ENTRANCE CONDENSATE DRAIN CONNECTION 3 4 NPT FEMALE 18 7 8 3 8 2 34 51 47 SUPPLY A RETURN 16 5 B CONTROL WIRE ENTRA...

Страница 20: ...20 MINIMUM CLEARANCES NOTE Roof overhang should be no more than 36 4 MIN 12 MIN 36 MIN FOR SERVICE 48 MIN 12 MIN 36 MIN FOR SERVICE...

Страница 21: ...n it Check the filter If it is dirty clean or replace it We strongly recommend a bi annual maintenance checkup be performed by a qualified service agency before the heating and cooling seasons begin R...

Страница 22: ...lignment per installation instructions Check refrigerant piping for rubbing and leaks Repair if necessary Check unit wiring to ensure it is not in contact with refrigerant piping or sharp metal edges...

Страница 23: ...Amps Condenser Fan Amps ELECTRICAL Total External Static Pressure Blower Wheel RPM TEMPERATURES Outdoor Air Temperature Return Air Temperature Cooling Supply Air Temperature Discharge Circuit 1 Heatin...

Страница 24: ...24 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com 2015 2016 Goodman Manufacturing Company L P...

Отзывы: