User Manual
16
2.3 Specifications
Model
39510
Input voltage
220-240 V @ 50 Hz
Power (W)
Stand-by power consumption
90
--
Max. volume flow (m³/min)
Service value (m³/min) / W
67
0,8
Sound power level (dB
A
)
60
Max. air velocity (m/s)
6,4
Protection class
I
Colour
chrome
Dimensions
B x H x T (cm)
Ø (cm)
56 x 53 x 18
45
Net weight (g)
4500
Device connection
Safety plug (type F, CEE 7/7) 90°
Cable length (m)
1,6
Tab. 6:
Specifications
3 Intended Use
This product is intended exclusively for private use and its intended
purpose. This product is not intended for commercial use. We do not
permit using the device in other ways like described in chapter “De-
scription and Function“ and „Safety Instructions“. Use the product only in dry interior
rooms. Not attending to these regulations and safety instructions might cause fatal
accidents, injuries, and damages to persons and property.
IPX0:
This product is not protected against water.
4 Installing and Operating
4.1 Preparing
1. Check the scope of delivery for completeness and integrity.
2. Compare the pecifications of product, power supply and peripherals.
They
must
be
identical.
4.2 Installing
Risk of injury by stumbling and falling
• Place, install and transport product, product ts and accessories
in
a
safe
way.
Injury by cutting
• Do not touch the edges of the rotor.
The rotor is sharp-edged.
1. Place the protective net with motor block and 4-step switch (3) with
the handle upwards on a level and firm surface.
Содержание 39510