Страница 2: ...8 11 1 Inspection 8 11 2 Iridium Antenna 8 11 2 1 Glareshield antenna installation 8 11 2 2 External antenna installation 8 11 2 3 Antenna testing 9 11 2 4 External screen installation 9 12 Wiring ADL120 10 12 1 1 25 D Sub connector voltage and aviation data 10 12 1 2 Antenna connector 11 13 Cooling 12 14 Post installation checkout 12 15 Documentation 12 16 Continued maintenance 12 17 Software and...

Страница 3: ...h any certification Please consult the minor change documentation for details 6 Disclaimer The ADL120 is provided as a non certified component The only basis on witch it can be installed is an appropriate minor change It is the sole responsibility of the user and installer that is installed and used in a legal way The device may stop working at any time Do not undertake flights you would not under...

Страница 4: ...ichever is applicable Do not reactivate the device until the problem has been investigated and resolved on the ground In case of a generator failure or similar situation requiring electric load shedding deactivate the ADL120 by pulling deactivating the aircraft circuit breaker for the device or pulling the cigarette lighter plug whichever is applicable 9 Dimensions Figures 1 shows the outside dime...

Страница 5: ...s can be used to attach the ADL120 to the aircraft Figure 2 show the exact dimensions The mechanical installation has to be adapted by the installer to the individual situation in the aircraft Figure 2 Location of the M4 threads on the front and back side of the ADL120 7mm 80mm 60mm 15mm 15mm 50mm 53mm 7mm 80mm 60mm 15mm 15mm 50mm 53mm ...

Страница 6: ... 1 02 10 04 2016 10 Optional external display As optional equipment an external display unit can be connected to the ADL120 The following figures show the dimensions of this screen Figure 1 Front dimensions of external screen 85 0 mm 85 0 mm ...

Страница 7: ...ADL120 Installation Manual 7 15 Revision 1 02 10 04 2016 Figure 2 Side view of external screen 10mm 55mm 20mm 10mm Display Bezel Connector and cable ...

Страница 8: ...our antenna does not come with such a connecter it must be crimped on the cable 11 2 1 Glareshield antenna installation In the case of a glareshield installation we recommend the Iridium SYN7391 C antenna This antenna has been tested with good results and the antenna does not incorporate any magnetic mount which could deviate the magnetic compass In general you should try to place the antenna as f...

Страница 9: ...place the aircraft next to a big hangar or similar objects obstructing the sky 11 2 4 External screen installation The drilling scheme on the external screen matches exactly the drilling scheme of our product ADL110 ADL110B Please look up the drilling pattern and installation options in the installation manual for these devices If possible avoid disconnecting the supplied cable from the display If...

Страница 10: ...ther flightplan sources please contact us Please note the Aviation In feature when connected must be activated in the software on the FPL page using the right side button FPL IN Please consult the installation manual of your FMS GPS for the required pin configuration Please not that usually the Garmin 430 530 devices will only be able to supply aviation out data on one RS232 port at a time Therefo...

Страница 11: ...ufacturer use WiFi reset Pin 2 22 Vcc 7V 30V DC 23 GND 24 GND 25 GND Table 2 25pin D SUB pin description 12 1 2 Antenna connector The device features a rear SMA input The Iridium SYN7391 C antenna will be delivered with the correct connector Figure 12 SMA connector ...

Страница 12: ...the iPad application If the GPS has not been running recently it may require several minutes to get a fix The Iridium system will usually get a satellite fix much faster In order to start an Iridium transmission the software will require a minimum of two Iridium signal quality bars as experience has shown that below this level transmissions may become unreliable Do a test run and download a METAR ...

Страница 13: ...le damage The device does not contain any field serviceable parts It the device is believed to be defunct please contact us for repair 19 Specifications ADL120 Voltage 7 to 30V Circuit breaker 1A Internal fuse 1 6A Maximum consumption 6W Temperature range operation 10 to 50 C Temperature range storage 20 to 70 C Weight excl installation material 425g ...

Страница 14: ...ADL120 Installation Manual 14 15 Revision 1 02 10 04 2016 20 Part number reference Partnumber Description ADL120 Datalink weather device EXT120 Optional external Touchscreen for the ADL120 ...