IM_ENG_REV0122_CODEPROX-N
INSTALLER
MANUAL
CODEPROX-N
Страница 1: ...IM_ENG_REV0122_CODEPROX N INSTALLER MANUAL CODEPROX N...
Страница 2: ...ID 6 9 1 5 PIN registration specific ID 6 9 1 6 PIN deletion 6 9 1 7 Card deletion 7 9 1 8 Deleting cards or PIN specific ID 7 9 1 9 Modify PIN 7 10 Other settings 7 10 1 Identification mode 7 10 1 1...
Страница 3: ...onics 48 W x 62 H x 25 D mm Electronics plus front cover 86 W x 86 H x 25 D mm Working temperature range 40 60 C Working humidity range 10 98 non condensing Lector CODEPROX N Diode Fixing blocks Screw...
Страница 4: ...ck 12V DC White 12V GND 1N4004 1 2 3 4 5 6 7 8 9 0 IMPORTANT Do not forget to connect the supplied diode 1N4004 in parallel to the lock release to protect the equipment 8 BASIC PROGRAMMING Basic progr...
Страница 5: ...ster card To Add user Rea d M as te r Car d Rea d Use r C ar d P IN nge rp rint 3 m es Rea d M as te r Car d Aga in 1 2 3 4 5 6 7 8 9 0 M aster card To Add user Rea d M as te r Car d Rea d Use r C ar...
Страница 6: ...highly recommended to modify the master code 9 1 1 CHANGE MASTER CODE Example 123456 0 987654 987654 Enter administrator mode MASTER CODE 0 NEW MASTER CODE 6 DIGITS NEW MASTER CODE 6 DIGITS Card regis...
Страница 7: ...en entered so it would be active for 15 seconds Default value 5 seconds The relay switches to ON OFF mode 10 OTHER SETTINGS 10 1 IDENTIFICATION MODE Example 987654 30 Example 987654 32 Enter administr...
Страница 8: ...e reader to factory defaults Restoring the configuration and the master code User information will be kept This process generates a MASTER card replacing the previous one In case you do not wish to re...
Страница 9: ...10 ON RST GND CLK SDA 3V Aout BUS M BUS PL AP AP NA1 C1 Lock release 12Vdc 270mA White 1 2 3 4 5 6 7 8 9 0 Enter administrator mode MASTER CODE 4 1 13 WIEGAND 13 1 CONNECTION DIAGRAM The following cha...
Страница 10: ...istered in iP Opener and your access will be granted Generate a user with credential type Other decimal following the next format when filling in the field Code 4 digit PIN X equals PIN 0000XXXX 5 dig...
Страница 11: ...light shines on the sensor after placing the reader the tamper alarm will be triggered NOTE The use of the reader integrated in the iP Opener system implies the loss of the buzzer and led states ther...
Страница 12: ...on Nexa Aluminium NX3000 CODEPROX N 20700018 kit for CODEPROX N reader mounting on Nexa Inox Due to the fact that the kit is supplied with the reader assembled in a special Nexa cover Front view of Ne...
Страница 13: ...e comunicaci n S A C Silici 13 Poligon Industrial Famadas 08940 Cornell del llobregat Spain golmar golmar es Tel 93 480 06 96 www golmar seguridad es Golmar reserves the right to make any changes with...