background image

Содержание R1804H

Страница 1: ...r conditioner MANUEL CL T UTILI E E FE N A ET Veuillez lire a_entivement et en entier ce guide d utilisation et les mesures de securit6 ci incluses avant de proceder a I instaflation et au fonctionnement de votre climatiseur N ICl P PIET Por favor lea las instrucciones de operaci6n y las precauciones de seguridad cuidadosa y totalmente antes de instalar y operar su acondicionador de aire de ventan...

Страница 2: ...ave you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our cha_ of Troubleshooting Tips first you may not need to cail for service at all Contact the authorized Service technician for repair or maintenance of this unit CaLl 1 800 243 0000 to locate the nearest ASC The air conditione...

Страница 3: ...erious injury L _ CAUTION This symb indicates the p ssibi ity f injury r damage t propertieson j m Meanings of symbols used in this manual are as shown below Be sure not to do this __ Be sure to foilow the instruction _ f _ WARNING 1 L J Otherwise it will cause electric shock or fire due to heat generation It will cause electric shock or fire due to heat generation It will cause electric shock or ...

Страница 4: ...se an injury Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc It may cause an electric shock It may cause a fire or deformation it may cause imperfect of the cabinet combustion Usecautionwhen handEing the use Grip it firmly and do not allow it to slip while holding it Useheavygloves to handle he caseif necessar...

Страница 5: ...lly controls cooling or heating but the fan runs continuously whenever the air conditioner ksin operation If the room is too warm turn the thermostat control clo_wise If the room is too cool turn the themostat ntroI anticlockwise Auto Swing ON Starts the operation of air swing OFF Stops the operation of air swing Please turn off Auto Swing when Operation Switch iS Off Auto Swing Off On OPERATION O...

Страница 6: ...ow from moving switch off the air swing switch at the desired position of the vane VERTICAL AIR TION CONTROL The vertical air direction is adjusted by moving the horizontal louver How to Attach Drain Pan The air conditioner employs a proper drain method whereby the con nsed water moisture removed from the air is drained to the outside In very humid weather and for reverse cycle models in the rever...

Страница 7: ... up and block the airflow This reduces the cooling capacity and also causes an accumulation of frost on the cooling coils 1 Open the inlet grille upward by pulling out the bosom of the inlet gdlle a in another case you can open the inlet grille downward by pulling out the top of the inlet grille b 2 Remove the air filter from the front gdlle assembly by pulling the air filter up or down slightly 3...

Страница 8: ...ion procedure 1 CABINET 2 HORIZONTAL AIR DEFLECTOR VERTICAL LOUVER 3 VERTICAL A_R DEFLECTOR HORIZONTAL LOUVER 4 AIR DISCHARGE 5 FRONT GRILLE 6 INLET GRILLE AIR INTAKE 7 AIR FILTER 8 CONTROL BOARD 9 POWER CORD 10 EVAPORATOR 11 CONDENSER 12 COMPRESSOR 13 BASE PAN 14 BRACE 15 COVER CONTROL 16 ELECTRIC HEATER ...

Страница 9: ...t and the wa l to prevent air and insects from getting into the room 8 The power _rd must be connected to an independent circuit The green wire must be grounded 9 Connect the drain tube to the base pan hole in the rear side if you need to drain _nsult a dealer Plastic hose or equivalent may be conn_t_ to the drain tube How to Use the Reversible Inlet Grille The grille is designed to clean the filt...

Страница 10: ...l opening widths from 26 to 41 The top and botom window sashes must open sufficiently to a owa cFear vertical opening of 18 from the bottom of the upper sash to the window stool 2 The stool offset height between the stool and sill must be less than 1 W 26 to 8 min Stool 1 than 1 1 4 I I Without framecurtain InstallationKits Contents TypeA 14 Ty_ B 7 Type C 5 Type D 2 Carriage Bol 2 Lock Nut 4 ...

Страница 11: ... off the backing and attach the Foam PE to the underside of the window sash Shippingscrews 4 Remove the backing from Foam PE with 3 holes and attach it to the bottom of the Top retainer bar 5 Attach the Top retainer bar on the top of the cabinet with 3 screws Type A 6 Insert the Frame guides into the bottom of the cabinet 7 Inse_ the Frame Curtain into the Top retainer bar and Frame guides Foam PE...

Страница 12: ...t bracket to the cabinet tra_ hole Use the first track hole aRer the silt bracket on the outer edge of the window sill Tiglhten the carriage bolt and the lock nut Be sure the cabinet slants ou_ard CAUTION DO NOT DRILL A HOLE IN THE BOTTOM PAN The unit is designed to operate with approximately 1 2 of water in bottom pan 4 Pull the bottom window sash down behind the Top retainer bar until they meet ...

Страница 13: ...er window sash and the lower window sash See Fig 12 Screw c Fig i0 Cord Screw Ty_ A Fig 1i 9 Attach the Window locking bracket with a screw Type C See Fig 13 10 Attach the front grille to the _binet by inserting the tabs on the grille into the tabs on the front of the cabinet Push the grille in until it snaps into place See Fig 14 11 Lift the inlet grille and secure it with a screw Type A through ...

Страница 14: ...ur protection against possible shock hazard FUSE Use a time delay fuse or circuit breaker Refer to serial plate for proper power supply requirements 230 208 and 230 208 VOLT UNITS These units are equipped with a three prong grounding plug on the power supply cord which must be plugged into a matching properly grounded three prong wall receptacle for your protection against possibie shock hazard if...

Страница 15: ...ner Make sure the air conditioner plug is pushed completely into the outlet Check the house fuseTcircuit breaker box and replace the fuse or reset the breaker If power failure o_urs turn the mode control to OFF When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the _mpressor overload_ Make sure there are no curtains blinds or furniture blocking the front of...