User Manual – Goldmund Mimesis 22M
Power Amplifier
10
7
SAFETY FEATURES Ctd
If the temperature rises too high, switch the amp off for quite some time. It is
strongly recommended to try to detect why the temperature has reached such a
level before operating the amp again.
- Protection against short-circuits.
If one output is short-circuited by accident and the current becomes too high, the
AC fuse may blow.
To replace the defective fuse, switch the amplifier off first. Then open the small
drawer located on the AC cord receptacle. The fuses are located inside. Change
the defective fuse.
Then switch the power on if the short-circuit has been detected and removed.
To avoid the fuses to blow, avoid to short-circuit the output terminals accidentally.
Always switch OFF the amp before trying any manipulation of the speaker
cables.
There is no risk to leave the speaker terminals unconnected when the amp is on.