Wiring
Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and
NEC electrical codes. To provide safe operation, the
AquaRite Long Life Electrolytic Chlorine Generato
r
must be properly grounded and bonded.
Input Power For stand alone operation:
Wire the
AquaRite Long Life Electrolytic Chlorine Generator
to the LOAD SIDE of the filter pump timer. It
is very important that the
AquaRite Long Life Electrolytic Chlorine Generator
is powered only when the
pump is
running.
Refer to the wiring label on the
AquaRite Long Life Electrolytic Chlorine Generato
r
as well as the diagram
below to determine correct wiring connections. The
AquaRite Long Life Electrolytic Chlorine Generator
is
shipped from the factory with the configuration jumpers in 240VAC position. If using 120VAC, move the
jumpers as shown below. For Canadian models, the
AquaRite Long Life Electrolytic Chlorine Generator
shall
be connected to a circuit protected by a class A ground fault interrupter. Be sure to connect the ground
wire to the green ground screw terminal located on the bottom of the enclosure.
{Diagram}
Bonding:
A lug used for bonding is attached to the bottom of the
AquaRite Long Life Electrolytic Chlorine
Generato
r
enclosure (see diagram below). The AquaRite Long Life Electrolytic Chlorine Generator must be bonded
with a
6 AWG copper wire (8 AWG USA) to the pool bonding system.
AquaRite Long Life Electrolytic Chlorine Generator Cell and Flow
Switch:
The
AquaRite Long Life Electrolytic Chlorine Generato
r
cell and flow switch cables are terminated with
connectors which plug into the
AquaRite Long Life Electrolytic Chlorine Generator
, for easy attachment and
removal. The door of the
AquaRite Long Life Electrolytic Chlorine Generator
must be open to access the
AquaRite Long Life Electrolytic Chlorine Generato
r
cell cable connector. The flow switch plugs into a
connector (similar to a telephone jack) located outside, on the bottom of the enclosure. Refer to the diagram
below for the location of these connections.