Wiring

 

Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and 
NEC electrical codes. To provide safe operation, the 

AquaRite Long Life Electrolytic Chlorine Generato

must be properly grounded and bonded.

 

 

Input Power For stand alone operation:

 

Wire the 

AquaRite Long Life Electrolytic Chlorine Generator 

to the LOAD SIDE of the filter pump timer. It 

is  very  important  that  the 

AquaRite  Long  Life  Electrolytic  Chlorine  Generator 

is  powered  only  when  the 

pump is

 

running.

 

 

Refer to the wiring label on the 

AquaRite Long Life Electrolytic Chlorine Generato

as well as  the  diagram 

below to determine correct wiring connections. The 

AquaRite Long Life Electrolytic Chlorine Generator 

is 

shipped from the factory with the configuration jumpers in 240VAC position. If using 120VAC, move the 
jumpers as shown below. For Canadian models, the 

AquaRite Long Life Electrolytic Chlorine Generator 

shall 

be connected to a circuit protected  by a  class  A  ground  fault interrupter.  Be sure to connect the ground 
wire to the green ground screw terminal located on the bottom of the  enclosure.

 

 
 
 
 
 

 

{Diagram} 

 
 
 
 

 

Bonding:

 

A lug used for bonding is attached to the bottom of the 

AquaRite Long Life Electrolytic  Chlorine 

Generato

enclosure (see diagram below). The AquaRite Long Life Electrolytic Chlorine Generator must be bonded 
with a

 

6 AWG copper wire (8 AWG USA) to the pool bonding system.

 

 

 

AquaRite Long Life Electrolytic Chlorine Generator Cell and Flow 
Switch:

 

The 

AquaRite Long Life Electrolytic Chlorine Generato

cell and  flow  switch  cables  are  terminated  with 

connectors which plug into the 

AquaRite Long Life Electrolytic Chlorine Generator

, for easy attachment and

 

removal. The door of the  

AquaRite Long Life Electrolytic  Chlorine  Generator  

must be  open to access  the 

AquaRite Long Life Electrolytic Chlorine Generato

cell  cable  connector.  The flow  switch  plugs  into a 

connector (similar to a telephone jack) located outside, on the bottom of the enclosure. Refer to the diagram 
below for the location of these connections.

 

 

{Diagram} 

Содержание AquaRite Long Life

Страница 1: ...2019 2660 2019 10 16 Part No AQR940 Electrolytic Chlorine Generator DOMESTIC READ THE LABEL AND MANUAL BEFORE USING REGISTRATION NUMBER 28325 5 PEST CONTROLS PRODUCT ACT...

Страница 2: ...acement cell for the AquaRite Long Life This cell must only be used on this model of chlorine generating device Read the label the Installation and Operation Manual of the AquaRite Long Life Electroly...

Страница 3: ...or generates a maximum output of hypochlorous acid equivalent to 0 45 kg of chlorine per day Do not use this device with bromide products KEEP OUT OF REACH OF CHILDREN NOTICE TO USER This pest control...

Страница 4: ...wing through the AquaRite Long Life Electrolytic Chlorine Generator cell Chlorine Check Salt Salt is below 2600 ppm AquaRite Long Life Electrolytic Chlorine Generator is working at reduced efficiency...

Страница 5: ...ALGAE in Residential Swimming Pools and Spas DOMESTIC READ THE LABEL AND MANUAL BEFORE USING REGISTRATION NUMBER 28325 5 PEST CONTROL PRODUCTS ACT Goldline Controls Inc A Hayward Company 61 Whitecap D...

Страница 6: ...his pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Products Act to use this product in a way that is inconsistent with t...

Страница 7: ...Table of Contents OPERATION General 1 Water Chemistry 1 Controls 6 Maintenance 8 INSTALLATION Mounting 9 Plumbing 10 Wiring 11 TROUBLESHOOTING Troubleshooting 14 WARRANTY Warranty 16...

Страница 8: ...quired to properly sanitize a pool varies due to bather load rainfall temperature and the pool s cleanliness Water Chemistry The table below summarizes the recommended water parameters The only specia...

Страница 9: ...he pool water balance Your water is properly balanced if the Si is 0 2 If the Si is below 0 2 the water is corrosive and plaster pool walls will be dissolved into the water If the Si is above 0 2 scal...

Страница 10: ...arily to the addition of water because of splashing backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl sal...

Страница 11: ...4 Diagram...

Страница 12: ...5 Diagram...

Страница 13: ...rination See description above REMOTELY CONTROLLED When illuminated indicates that a remote pool automation control Goldline Aqua Logic Pentair Intellitouch Polaris Eos etc is controlling the AquaRite...

Страница 14: ...7 Generator has stopped producing chlorine Inspect clean or replace if necessary...

Страница 15: ...to generate enoughchlorine To find the optimum Desired Output setting start at approximately 50 Test the chlorine level every few days and adjust the dial up or down accordingly It usually takes 2 3 a...

Страница 16: ...hat a buildup on the AquaRite Long Life Electrolytic Chlorine Generator cell indicates that there is an unusually high calcium level in the pool old pool water is usually the cause If this is not corr...

Страница 17: ...1 Spring Start up DO NOT turn the AquaRite Long Life Electrolytic Chlorine Generator on until the pool water chemistry has been brought to the proper levels This information can be found on page 1...

Страница 18: ...Life Electrolytic Chlorine Generator system Mounting the AquaRite Long Life Electrolytic Chlorine Generator Control The AquaRite Long Life Electrolytic Chlorine Generator is contained in a raintight...

Страница 19: ...enerator cell Configurations 2 and 3 allow for chlorination of both the pool and spa during spa spillover operation but prevent over chlorination of the spa during spa only operation Never use configu...

Страница 20: ...ator shall be connected to a circuit protected by a class A ground fault interrupter Be sure to connect the ground wire to the green ground screw terminal located on the bottom of the enclosure Diagra...

Страница 21: ...52 meters 500 feet apart Any outdoor rated 4 conductor cable can be used Refer to each manufacturer s instructions and the wiring diagrams below for proper wiring connection to the AquaRite Long Life...

Страница 22: ...Polaris Attach wires to proper screw terminals as shown below Note that screw terminal 1 is marked on the Polaris PCB Diagram 13...

Страница 23: ...s not pushed for 30 seconds the display will revert back to the standard salt display Common Problems and Solutions 1 Power LED not on Check to make sure either 120VAC or 240VAC input power is connect...

Страница 24: ...ted the cell may be worn and need replacement 8 Possible causes of little or no free chlorine residual AquaRite Long Life Electrolytic Chlorine Generator switch in OFF position Desired Output adjustme...

Страница 25: ...pool automation or chlorination product or part with a part number other than AQRITE AQ TROL AQ LOGIC AQL P AQL PS or AQL CL to be free from defects in material or workmanship under normal use and se...

Страница 26: ...Diagram Goldline Controls Inc A Hayward Company N Kingstown RI 02852 USA 888 921 POOL 7665 092009 Copyright 2004 Goldline Controls Inc...

Страница 27: ......

Отзывы: