Electrical Requirements
Emissions listing for Updraft and Downdraft units:
Updraft:
3.6 mg particulates/cubic meter of exhaust air
Downdraft:
1 mg particulates/cubic meter of exhaust air
The following power supply must be provided:
Note:
Twin Models have two kettles, a dual updraft system, and two linked fire
suppression systems (some Exports exclude Fire Suppression System). Two plugs,
one for each side of popper, are supplied with Twin Models (Domestic units
include two wall receptacles).
DOMESTIC UNITS:
120/208 or 120/240 V~, 60 Hz
(reference unit Data Plate for Wattage requirement)
Twin Models are supplied with two plugs, one for each side of popper.
Domestic units are designed to operate on single phase, 50 AMP, 4 wire supply, 120/208
or 120/240 V~ (2 Hot, 1 Neutral, 1 Ground). All electrical components in this machine are
120 V (motors, heat elements, lights, etc.) and therefore require “Hot to Neutral” connection
(
NOT
“Hot to Hot”). A 50 AMP wall receptacle (
NEMA 14-50) is supplied with the machine.
The receptacle will accept the attachment plug on the machine and must be used; reference
the Receptacle Wiring Diagram for NEMA 14-50 for receptacle installation instructions.
EXPORT UNITS:
220-230 V~, 50/60 Hz
(reference unit Data Plate for Wattage requirement)
Potential Electrical Variations: 220 V~, 60 Hz
Twin Models are supplied with two plugs, one for each side of popper.
Export units
are designed to operate on single phase, 16 AMP, 4 wire supply, 230 V~
(2 Hot, 1 Neutral, 1 Ground). All electrical components in this machine are 230 V (motors,
heat elements, lights, etc.) and therefore require “Hot to Neutral” connection (
NOT
“Hot to
Hot”
). A certified electrician must supply and install the wall receptacle for this unit;
reference the Receptacle Wiring Diagram for Export Units.
Australia - 52 oz. units
are designed to operate on single phase, 36 AMP, 2 wire supply,
plus ground. All electrical components in machine are 230 V (motors, heat elements,
lights, etc.) A certified electrician must supply and install the wall receptacle for this unit.
DANGER
Machine must be properly grounded to prevent electrical shock to personnel.
Failure to do so could result in serious injury, or death.
DO NOT immerse any part of this equipment in water.
DO NOT use excessive water when cleaning.
Keep cord and plug off the ground and away from moisture.
Always unplug the equipment before cleaning or servicing.
Make sure all machine switches are in the OFF position before plugging the
equipment into the receptacle.
008_051514
A certified electrician must furnish sufficient power for proper machine operation and install any
supplied receptacle (reference unit Data Plate for model specific Volts AC, Hertz, and Wattage