Electrical Requirements
The following power supply must be provided:
2011 Series:
120/208 V~ or 120/240 V~, 5752 W, 60 Hz
Units are designed to operate on single phase, 30 AMP, 4 wire supply, 120/208 or
120/240 V~ (2 Hot, 1 Neutral, 1 Ground). All electrical components in this machine are 120 V
(motors, heat elements, lights, etc.) and therefore require “Hot to Neutral” connection (NOT
“Hot to Hot”). A 30 AMP wall receptacle (NEMA L14-30) is supplied with the machine. The
receptacle will accept the attachment plug on the machine and must be used, reference the
Receptacle Wiring Diagram for NEMA L14-30 for receptacle installation instructions.
DANGER
Machine must be properly grounded to prevent electrical shock to personnel.
Failure to do so could result in serious injury, or death.
DO NOT immerse any part of this equipment in water.
DO NOT use excessive water when cleaning.
Keep cord and plug off the ground and away from moisture.
Always unplug the equipment before cleaning or servicing.
Make sure all machine switches are in the OFF position before plugging the
equipment into the receptacle.
008_051514
A certified electrician must furnish sufficient power for proper machine operation and install any
supplied receptacle. We recommend this equipment be on a dedicated and protected circuit.
Failure to wire properly will void the warranty and may result in damage to the machine. It is Gold
Medal Products Co.’s recommendation that this machine be plugged directly into a wall outlet. The
use of extension cords is not recommended due to safety concerns, and may cause sacrificed
and/or reduced performance. Make sure cord is located to prevent a trip hazard or unit upset.
Receptacle Wiring Diagram for NEMA L14-30 (120V Units)
A certified electrician must follow the IMPORTANT instructions shown for installation of the
L14-30 Receptacle (Gold Medal Item No. 82208) provided with the unit.
If the receptacle is wired incorrectly, the heat elements/kettle and other electrical components could
be at 208 or 240 V potential instead of the needed 120 V, resulting in excessive temperatures in
the heat elements (i.e.: kettle) and possible fire, and/or damage to electrical components.
NEMA L14-30 (30 AMP Receptacle) - Front and Back View
Green Terminal
Connect to Green
(Ground) Wire
Brass Terminal
Connect to Red
(Hot) Wire
G
Y
Brass Terminal
Connect to Black
(Hot) Wire
Silver Terminal
Connect to White
(Neutral) Wire
X
W