© 2020 Go Power! 

 

Boost Reconnect 

Charging Voltage 

13.2V 

13.2V 

13.2V 

13.2/26.4V 

Low Voltage Reconnect 

Voltage 

12.6V 

12.6V 

12.6V 

12.2/24.4V 

Under Voltage Warning 

Reconnect Voltage 

12.2V 

12.2V 

12.2V 

12.4/28.8V 

Under Volt. Warning 

Volt. 

12.0V 

12.0V 

12.0V 

12.0/24.0V 

Low Volt. Disconnect Volt.  11.1V 

11.1V 

11.1V 

11.0/22.0V 

Discharging Limit Voltage  10.6V 

10.6V 

10.6V 

10.5/21.0V 

Equalize Duration  

120min.  —— 

120min. 

  —— 

Boost Duration  

120min.  120min.  120min. 

120min. 

 

1.  When the battery type is sealed, gel, flooded, the adjusting range of 

equalizing duration is 0 to180min and boost duration is 10 to180min. 

2. When setting a lithium battery type, (for example: a LiFePO

4

) use these rules 

when setting voltage parameters.  

  Ov

er Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize 

Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > 

Boost Reconnect Charging Voltage. 

  Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage 

  Low Voltage Reconnect 

Voltage > Low Voltage Disconnect Voltage ≥ 

Discharging Limit Voltage. 

  Under Voltage Warning Reconnect Voltage > Under Voltage Warning 

Voltage ≥ Discharging Limit Voltage.

 

  Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage. 

 

6.0 

Errors & Troubleshooting 

 
No Power to LCD Screen 

Solution 1 

Check the connection between the DuraLite Kit and the controller, and the 

controller and the battery. The controller requires a minimum voltage of 8v to run.  

 

 

 

Содержание Dura Lite Solar Controller

Страница 1: ...Solar Controller User Manual ________________________________________________________________________ 2020 Go Power User Manual 30 amp Single Bank Solar Controller...

Страница 2: ...T SAFETY INSTRUCTIONS 4 3 0 Choosing a Battery 6 4 0 DuraLite Kit Wiring Diagram 6 5 0 Operating Instructions 6 5 1 Battery Charging Profile Chart 8 6 0 Errors Troubleshooting 9 7 0 Display Symbols 10...

Страница 3: ...ystem voltage and is rated for a maximum continuous DC input current of 37 5A and input voltage of 35VDC Per National Electrical Code NEC article 690 7 and 690 8 PV module nameplate ratings must be mu...

Страница 4: ...Current 30A Max PV Open Circuit Voltage 50V Battery Type Sealed AGM Gel Flooded Lithium 1 12V and Lithium 2 24V Self consumption 4 2mA 12V 2 6mA 24V Temperature Compensate Coefficient 3mV 2V Default C...

Страница 5: ...ion Use extreme caution when working with electricity and when handling and working around batteries Observe correct polarity Reverse polarity of the Battery 1 terminals will cause the controller to g...

Страница 6: ...fety instructions 4 0 DuraLite Kit Wiring Diagram The SOLAR CONTROLLER Maximum 37 5A rating is based on a 30 amp total maximum short circuit current rating Isc from the solar modules nameplate ratings...

Страница 7: ...ess the SET button to clear the generated energy 3 Switch the battery temperature unit Press the SET button and hold 5s under the battery temperature interface 4 Battery type Battery type Sealed Gel F...

Страница 8: ...m Sealed Gel Flooded Lithium Over Voltage Disconnect Voltage 16 0V 16 0V 16 0V 14 6 29 2V Charging Limit Voltage 15 0V 15 0V 15 0V 14 4 28 8V Over Voltage Reconnect Voltage 15 0V 15 0V 15 0V 14 4 28 8...

Страница 9: ...min and boost duration is 10 to180min 2 When setting a lithium battery type for example a LiFePO4 use these rules when setting voltage parameters Over Voltage Disconnect Voltage Charging Limit Voltage...

Страница 10: ...ing Solution This is an Over Discharge Error The battery voltage is too low Connect the DuraLite kit to charge the battery 7 0 Display Symbols Icon Motion Issue Solid The system is normal but not char...

Страница 11: ...ed when compared with readings from another voltmeter There may be a slight difference between the battery voltage displayed on the SOLAR CONTROLLER display and the battery voltage measured at the bat...

Страница 12: ...oblems is split into three sub sections grouped by symptoms involving key components A multimeter or voltmeter may be required for some procedures listed It is imperative all electrical precautions st...

Страница 13: ...ssible Cause Excessive voltage drop from batteries to controller due to loose connections small wire gauge or both How to tell Check the voltage at the controller battery terminals with a voltmeter an...

Страница 14: ...clean tight and secure Continue with the solutions below for additional help on low current readings Current Reading Less than expected Time of Day Daytime clear sunny skies Possible Causes 1 Current...

Страница 15: ...itive and negative terminals of each module junction box with either the positive or the negative wires disconnected from the terminal Remedy 2 Reconnect in correct configuration Tighten all connectio...

Страница 16: ...oper hook up Acts of God including lightning floods earthquakes fire and high winds Damage in handling including damage encountered during shipment This warranty shall be considered void if the warran...

Страница 17: ...ER _______________________________________________________________________ 17 2020 Go Power 2019 GO POWER 201 710 Redbrick St Victoria British Columbia Canada V8T 5J3 MOBI_MAN_SOLAR CONTROLLER _RevF g...

Отзывы: