D6037 

- SIL 2 Switch/Proximity Detector Repeater Transistor Out                             

 

G.M. International ISM0409-0 

SIL 2 Switch/Proximity Detector Repeater 

Transistor Out, DIN-Rail and 

Termination Board, Models D6037S, D6037D 

D6037S - D6037D 

INSTRUCTION MANUAL 

Содержание D6037S

Страница 1: ...itch Proximity Detector Repeater Transistor Out G M International ISM0409 0 SIL 2 Switch Proximity Detector Repeater Transistor Out DIN Rail and Termination Board Models D6037S D6037D D6037S D6037D INSTRUCTION MANUAL ...

Страница 2: ...ls D6037D 12 mA for 1 channel D6037S with short circuit input and transistor closed typical Power dissipation 0 53 W for 2 channels D6037D 0 30 W for 1 channel D6037S with 24 V supply voltage short circuit input and transistor closed typical Isolation Test Voltage In Out 1 5 kV In Supply 1 5 kV In In 500 V Out Supply 500 V Out Out 500 V Input switching current levels ON 2 1 mA 1 9 to 6 2 mA range ...

Страница 3: ...stem In field programmability by DIP Switch TÜV Certification TÜV Functional Safety Certification High Density two channels per unit Simplified installation using standard DIN Rail and plug in terminal blocks with or without Power Bus or customized Termination Boards Input Ch 1 for Proximity or Voltage free Contact Terminal block connections Input Ch 1 for Proximity or Voltage free Contact Input C...

Страница 4: ...ge free Contact In 2 Proximity voltage free Contact voltage free Contact voltage free Contact R1 R2 R1 R2 Resistors R1 R2 used with voltage free contact required for line fault detection Resistors R1 R2 used with voltage free contact required for line fault detection MODEL D5037S 6 1 2 Out SIL 2 7 8 Termination board connector Power and Fault Bus Supply 24 Vdc F 5 In Proximity voltage free Contact...

Страница 5: ... Termination Board D6037 unit can be mounted with any orientation over the entire ambient temperature range Electrical connection of conductors up to 2 5 mm are accommodated by polarized plug in removable screw terminal blocks which can be plugged in out into a powered unit without suffering or causing any damage The wiring cables have to be proportionate in base to the current and the length of t...

Страница 6: ...in fault condition 7 NO 8 OR NC 7 8 7 NO 8 OR NC 7 8 1 OFF 1 ON NC 1 2 1 NO 2 Output 1 NO 2 Output NC 1 2 Position in fault condition 1 2 2 ON 2 OFF Input Input Output Input Output Input CH2 Setting Line fault detection IN OUT Operation NO NC or NC NO NO NO or NC NC Disabled switch proximity sensor Enabled proximity sensor or switch with end of line resistors de energizes transistor in fault condi...

Страница 7: ...4 ON CH1 3 4 not used For SIL Application For SIL Application Line fault detection SW1 Disabled switch proximity sensor OFF Enabled for SIL application proximity sensor or switch with end of line resistors detects field open circuit and short circuit de energizes transistor in fault condition ON IN OUT Operation SW2 NO NC or NC NO ON NO NO or NC NC for SIL application OFF D6037S Configuration Summ...