AISS120 Instruction Manual
17
TROUBLESHOOTING
Issue
Possible Cause and Remedy
No data is being received by the chart
plotter
Check that the power supply is connected
correctly.
Check that the connections to the chart
plotter are correct.
Check that the VHF antenna is correctly
connected in accordance with the
instructions in the manual
The power indicator is not illuminated
is not illuminated
Check that the power supply is connected
correctly.
The reception indicator is flashing
but AIS targets are not displayed on
the chart plotter is flashing but AIS
targets are not displayed on the chart
plotter
Check the chart plotter NMEA port
configuration is set to receive AIS data
Check the chart plotter display settings are
configured to show AIS targets
Consult the chart plotter manufacturers
documentation
The power indicator is illuminated but
the reception indicator is not flashing
to indicate receipt of AIS messages
Check there are vessels equipped with AIS
transceivers in your area
Check the VHF antenna is correctly installed
and connected
If the guidance given in the table above does not rectify the problem you are
experiencing please contact your dealer for further assistance.