4. Now that the air filter housing cover has been
removed, proceed to remove the air filter by pulling it
out towards you.
5. Wash the air filter in solvent or kerosene and allow to dry.
6. Lubricate the filter using clean motor oil.
7. Thoroughly squeeze the filter removing excess oil.
8. Replace air filter back into the
engine (Fig. W).
9. Reinstall the air cleaner cover
by inserting the lower tab in
the bottom latch on the air
filter housing. Continue to
replace the air cleaner cover
by making sure that the top
tab has been secured into the
top latch (Fig. X).
10. Secure the maintenance cover (5) back onto the side
panel of the generator, and tighten the cover screw
securely (20) (Fig. Y).
IMPORTANT.
Never run the engine without the air filter
element in place.
Cleaning
1. Keep your machine clean. The outside of the machine
can be cleaned using a damp soft cloth with a mild
detergent if required. Never use water to clean the
generator as it may cause damage to internal parts.
2. Some maintenance products and solvents may damage
the plastic parts; these include products containing
benzene, trichloroethylene, chloride and ammonia.
3. Use a vacuum to clean air inlet and outlet louvers of
the alternator.
4. Take special care to keep the ventilation inlets/outlets
free from obstruction; cleaning with a soft brush followed
by a compressed air jet will usually be sufficient to ensure
acceptable internal cleanliness.
5. Wear eye protection when carrying out cleaning.
Repairs
Only an authorised service centre should repair the generator.
CAUTION.
Do not use cleaning agents to clean the
plastic parts of the tool. A mild detergent on a damp cloth
is recommended.
Transportation
When transporting the generator please make sure that it is
in the upright position at all times, with the fuel air breather
on top of the fuel cap in the off/closed position.
General inspection
Regularly check that all the fixing screws are tight.
They may vibrate loose over time.
W
Y
X