4

 SIG A8

 SIG A7

 SIG A6

 SIG A5

 SIG A4

 SIG A3

 SIG A2

 SIG A1

(3) Network signal input, signal cascaded itself by network cable

It  is  very  important  to  correctly  understand  the  port  number  for  the  intelligent  address  settings  in  the 

control software. Please make sure select correct controller port and signal divider port before you start to set 

the address as shown below picture.

You can only use the intelligent setting method to set the display address of the LED screen if there is 

one  or  more  signal  divider  connected  with  VSP-F2L4  controller.  Please  select  correct  controller  port  and 

signal divider port , otherwise, you won't see the image change of the LED screen when you start the address 

setting.

Each  time  can  only  set  one  signal  divider  output  port's  addresses  of  LED  panels.  Please  remember  to 

rebuild a simulator diagram firstly when you set another port's addresses of LED panels.

Function description

Network

 

signal

cascade output

Network

 

signal

input to Group 

A

Содержание SDV08

Страница 1: ...Glux SDV divider manual GLUX Visual Effects Tech Shenzhen Co Ltd...

Страница 2: ...l Cascade of Signal Divider 2 1 Interface De nition of Signal Divider 2 2 Common Methods for Signal Cascade Chapter3 Function Introduction of Signal Divider 3 1 Signal Transformation 3 2 Signal Distri...

Страница 3: ...B signal input output port SIG IN represents group B signal input port SIG OUT represents group B signal cascade output port Optical ber signal input output port IN OUT stand for optical ber signal i...

Страница 4: ...A4 SIG A3 SIG A2 SIG A1 Equal 1 3 Outline Size and Installation Diagram Hanging Handing parts 1 4 Structural Diagram Hanger Screw BM4 50 SDV Top box Hanger inner mat Screw PA2 8 Optical ber block Scre...

Страница 5: ...ade way SIG B4 SIG B3 SIG B2 SIG B1 SIG A4 SIG A3 SIG A2 SIG A1 SIG B8 SIG B7 SIG B6 SIG B5 SIG A8 SIG A7 SIG A6 SIG A5 Optical fiber signal cascade output Signal Divider 1 SDV 1 1 Optical ber signal...

Страница 6: ...only use the intelligent setting method to set the display address of the LED screen if there is one or more signal divider connected with VSP F2L4 controller Please select correct controller port and...

Страница 7: ...he backup signal input port and connect to the last LED panel s output Thereby ensuring there are main signal and backup signal on the screen at the same time 4 Application Example Application Example...

Страница 8: ...1024 384 we can calculate W 1024 H 384 according to the signal horizontal segmentation of the VSP F2L4 controller The parameter interface showed as below Step3 Addresses Setting of Signal Divider We c...

Страница 9: ...way of port OUT2 The address distribution of B1 is as the red arrow shown below Addresses Setting steps for Main Signal Main Signal A1 Port setting Controller port A Signal divider port 1 1 represents...

Страница 10: ...on way of port OUT1 The address distribution of A2 is reverse to the A1 as the red arrow shown below Backup signal B2 Port setting Controller port B Signal divider port 2 2 represents B2 Fill in the c...

Страница 11: ...parameter interface and click Save button when you have completed all of the address settings Otherwise once you reboot the controller the data for addresses setting will be lost and the image of the...

Страница 12: ...The way to set the address of Port A2 Select Controller port A Divider port 2 Rows 6 Columns 4 rebuild a simulator diagram Number the addresses blocks of the second column to set the addresses of por...

Страница 13: ...f the fourth column to set the addresses of port A4 as shown below Please return to the parameters interface and click Save button to save the addresses setting data when you complete all addresses se...

Страница 14: ...onal injury use the appropriate power line Please only use the dedicated power cord for this product which acquire the international regional certi cation Connect and Disconnect Properly When add Conn...

Страница 15: ...alZone NanshanDistrict Shenzhen China tel 86 755 88866999 fax 86 755 86241789 Factory GluxIndustrialZone Donghuan2ndRoad LonghuaNewDistrict Shenzhen GuangdongChina tel 86 755 29174931 fax 86 755 86232...

Отзывы: