background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from software version: 1.0  

 

 

 

[email protected] 

www.glp.de

Instruction Manual

 

Содержание impression X1

Страница 1: ...from software version 1 0 support glp de www glp de Instruction Manual ...

Страница 2: ...GLP German Light Products GmbH impression X1 manual v1 0 from software version 1 0 2 Notes ...

Страница 3: ...8 3 1 3 Mounting in sideways Position 9 3 2 Securing the Fixture 10 3 3 Connections 10 3 3 1 Power Supply 10 3 3 2 NEUTRIK powerCON 10 3 3 3 DMX 11 4 The Menu Field 12 5 DMX Channel Selection DMX Protocol 14 5 1 Normal Mode 18 DMX channels 14 5 2 Compressed Mode 14 DMX channels 16 6 6 Maintaining and Cleaning 18 6 1 Safety regulations 18 6 2 Maintenance and Interval rule of thumb 18 7 Technical Sp...

Страница 4: ...actively and passively cooled 2 Arm of device 3 LCD Display Menu data entry 4 Base with various connectors air in outlets and mounting system 5 Fuse holder on the bottom Base sideview base side 1 6 7 5 3 1 2 4 base side 2 8 9 6 Mains Out powerCON grey 7 DMX Output 5 pin 8 DMX Input 5 pin 9 Mains In powerCON blue bottom view ...

Страница 5: ...o wait at least 15 minutes after disconnecting the mains power before handling the fixture Pay attention to possible hot parts of the fixture The I IM MP PR RE ES SS SI IO ON N X X1 1 is a High Tech Product To guarantee a smooth operation it is necessary to respect the following rules The manufacturer of this device will not take responsibility for damages through any disregard of the information ...

Страница 6: ...ir maintenance and installation work shall be done by qualified or GLP certified staff only You need to pay attention to the common rules of technology that are not explicitly mentioned in this manual 8 Use only original GLP spare parts Any structural modification of the system will terminate all warranty claims 9 Please keep this instruction manual for future reference 10 Should you have any ques...

Страница 7: ... attention to the regulations of BGV C1 former VBG 70 DIN VDE 0711 217 and BGI 810 3 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR RE ES SS SI IO ON N X X1 1 standing on the floor sideways or hanging different connectors are available Through this a safe and firm installation is assured You ll find dedicated M10 threads on the bottom si...

Страница 8: ...tional securing is usually not required Please pay attention to an even and gripping surface 3 1 2 Mounting in hanging position To operate the I IM MP PR RE ES SS SI IO ON N X X1 1 in a hanging position please use a half coupler clamp This can be mounted directly to the bottom side of the fixture It should be attached centrically with a M10 mm thread bolt max length 11mm Attention Never use a long...

Страница 9: ... side of the base They should be attached with M10 mm thread bolts max length 11mm This technique is necessary to cope with the torque which accrues in this mounting position Never use the Mounting in hanging position technique described above to fasten the fixture in the sideways position A safe and sound installation cannot be assured in this way In addition this can damage the fixture base Atte...

Страница 10: ...CON AC connector Connected load 85 VA W T2A micro fuse 5x20mm Please also see the printing on the case Disconnect from the mains supply for changing the fuse and use only the above described micro fuse type 3 3 2 NEUTRIK powerCON The IMPRESSION X1 is fitted with NEUTRIK powerCON locking 3 conductor AC connectors The grey connector must be used to draw AC mains power from the fixtures throughput so...

Страница 11: ...to different mechanical dimensions only the newer version of these two can be used for i im mp pr re es ss si io on n X X1 1 fixtures You can identify the correct version by the imprint on the side and the NEUTRIK Logo on the lock latch 3 3 3 DMX USITT DMX 512 Standard input output in 5 pin connectors Pin 1 Ground Pin 2 Pin 3 Pin 4 5 N C The DMX Addressing starts at the DMX Address 001 ...

Страница 12: ...ent Pattern Manual control for Pattern channel bank Speed Movements Manual control for Pan Tilt movements Pan Tilt Movements Manual control for Pan Tilt movements Special Manual control for Special functions White Temperature Manual control for Color temperature Dimmer Manual control for Dimmer Shutter Manual control for Shutter White Manual control for White Blue Manual control for blue Green Man...

Страница 13: ...tem below Pan Tilt Movements Instantaneous value for Pan Tilt movements Special Instantaneous value for Special White Temperature Adjustment of the color temperature for WHITE Dimmer Instantaneous value for Dimmer Shutter Instantaneous value for Shutter White Instantaneous value for White Blue Instantaneous value for Blue Green Instantaneous value for Green Red Instantaneous value for Red Color Wh...

Страница 14: ... Color 09 Lavender 1 72 79 Color 10 Malve 1 80 87 Color 11 Magenta 1 88 95 Color 12 Pink 1 96 103 White CTO 3200K 104 111 White 5600K 112 119 White CTB 7200K 120 127 Rainbow Effect Stop 2 128 Rainbow Effect 3 slow fast 129 223 Random colors slow fast 224 255 6 Red Color mixing system Red 0 100 0 255 7 Green Color mixing system Green 0 100 0 255 8 Blue Color mixing system Blue 0 100 0 255 9 White C...

Страница 15: ... Pan 4 0 24 25 Pan 4 90 26 27 Pan 4 180 28 29 Pan 4 270 30 31 Tilt size phase see Pan 32 63 Pan Tilt size phase see Pan 64 95 Pan Tilt inverse size phase see Pan 96 127 Circle size phase see Pan 128 159 Circle inverse size phase see Pan 160 191 Lying eight size phase see Pan 192 223 Random movement size phase see Pan 224 255 15 Pan Tilt Pan Tilt movement speed from controller 0 1 Speed Pan Tilt sl...

Страница 16: ...10 Malve 1 80 87 Color 11 Magenta 1 88 95 Color 12 Pink 1 96 103 White CTO 3200K 104 111 White 5600K 112 119 White CTB 7200K 120 127 Rainbow Effect Stop 2 128 Rainbow Effect 3 slow fast 129 223 Random colors slow fast 224 255 6 Red Color mixing system Red 0 100 0 255 7 Green Color mixing system Green 0 100 0 255 8 Blue Color mixing system Blue 0 100 0 255 9 White Color mixing system White 0 100 0 ...

Страница 17: ...art colors but will still execute the rainbow effect synchronously If you choose a color different from the ones marked with 1 in the tables above the rainbow start color will be red 2 Rainbow effect Stop will pause this function After resuming the rainbow effect will be continued from the current color 3 The Rainbow effect will run synchronously only if started from one of the predefined colors s...

Страница 18: ...ee cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should alcohol or solvents be used 6 1 Safety regulations Pull out the mains power plug Wait min 15 minutes after disconnecting power to allow the fixture to cool down 6 2 Maintenance and Interval rule of thumb The contamination of the fixture depends on the environment details Hence no general guidelines ...

Страница 19: ...mized for maximum presentable color space Optical System Full RGBW High efficient Collimator cluster Interchangeable lens carrier with 7 beam angle as standard option Shutter Dimmer 8 16 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Pulse Effects Continuous Dimmer 0 100 DMX Control Standard USITT DMX 512 5 pin XLR Pin 3 Pin 2 Ground Pin 1 Pin 4 5 N C The DMX Addressi...

Страница 20: ...GLP German Light Products GmbH impression X1 manual v1 0 from software version 1 0 20 8 Dimensions ...

Страница 21: ...2 M Maintenance 18 Menu Field 12 Micro fuse 10 Mode key 12 Mounting 7 Mounting in hanging Position 8 Mounting in sidewise Position 9 Mounting on the Floor 8 N NEUTRIK powerCON 10 Normal Mode 14 O Optical parts 18 P Pan Movement 19 Power Supply 10 S Safety distance 7 Safety Instructions 5 Secure the Device 10 Software Version 1 T Technical Specifications 19 Tilt Movement 19 U Up Down keys 12 V VBG ...

Страница 22: ...GLP German Light Products GmbH impression X1 manual v1 0 from software version 1 0 22 ...

Отзывы: