AC mains power
30
Fusion Stick FS16Z
User Manual Rev. A
Installing power connectors
If you intend to draw power from convenience receptacles / consumer mains power
sockets, it is possible to install a suitable cord cap / power plug on the supplied power
cord / input cable. If you do this, check that the cord cap / plug is rated minimum
250 V, 16 A, that it has a connection to ground / earth and that it has an integral cable
grip. Follow the cord cap / plug manufacturer’s assembly instructions.
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow
the instructions given in the Support area of the Neutrik website at
Live or L
Neutral or N
Ground / Earth or
US system
Black White
Green
EU system
Brown Blue Yellow/green
Connecting multiple fixtures to power in a chain
You can connect fixtures to power in a daisy-chain to simplify your power circuit
layout.
FS16Z fixtures have 2.5 mm2 internal wiring from Power IN to Power THRU connectors.
Warning!
Do not connect more than three (3) FS16Z fixtures in total to power
in one chain at 100-120 V, 60 Hz. Do not connect more than six (6) FS16Z
fixtures in total to power in one chain at 200-240 V, 50 Hz.
The power input cable supplied with the fixture is rated 16 A maximum. Add
together the maximum current draw ratings of all the devices that you
intend to connect to power in a daisy chain and do not create a chain with
a total maximum current draw of more than 16 A, or you will create a risk of
fire and electric shock.
To connect fixtures to power in a chain:
1. Obtain power relay cables that have male and female Neutrik powerCON TRUE1
connectors. Cables must be minimum 14 AWG or 1.5mm
2
, rated minimum 16 A
and suitable for the environment and application.
2. Connect the power input cable to the Mains IN socket of the first fixture as
described under ‘Connecting to power’ on page 29.
3. Connect a relay cable to the Mains OUT / THRU socket of the first fixture and to the
Mains IN socket of the second fixture.
4. If you are using 100-120 V, 60 Hz AC mains power you can continue connecting
FS16Z fixtures Mains OUT / THRU socket to Mains IN socket until the chain contains a
maximum of three (3) fixtures in total. If you are using 200-240 V, 50 Hz AC mains
power you can continue connecting fixtures Mains OUT to Mains IN until the chain
contains a maximum of six (6) fixtures total.
Содержание Fusion Stick FS16Z
Страница 1: ...Fusion Stick FS16Z User Manual Software version 1 0 0 0...
Страница 14: ...www glp de Avoiding damage to the fixture 14 Fusion Stick FS16Z User Manual Rev A...
Страница 16: ...www glp de FS16Z overview 16 Fusion Stick FS16Z User Manual Rev A...
Страница 49: ...German Light Products DMX control modes overview Fusion Stick FS16Z User Manual Rev A 49...
Страница 61: ...German Light Products DMX MODE 9 Fusion Stick FS16Z User Manual Rev A 61...
Страница 67: ...German Light Products Fusion Stick FS16Z User Manual Rev A 67...
Страница 70: ...www glp de 70 Fusion Stick FS16Z User Manual Rev A...
Страница 72: ...www glp de 72 Fusion Stick FS16Z User Manual Rev A...
Страница 73: ......