Glow-worm Miami GF Скачать руководство пользователя страница 1

Hepworth Heating Ltd.,

Nottingham Road, Belper, Derbyshire. DE56 1JT

General/Sales enquiries:

Tel: (01773) 824141  Fax: (01773) 820569

One Contact Local Service

Customer Services:

Tel: (01773) 828100

Fax: (01773) 828070

221917C.06.02

All replacement parts

All labour charges

All call-out charges

Guarantee Registration

Miami GF

Radiant Convector Gas Fire

This is a Cat I

2H

 Appliance

Reference in these instructions to British Standards and Statutory

Regulations/Requirements apply only to the United Kingdom.

For Ireland the rules in force must be used.

The instructions consist of three parts, User, Installation and Servicing Instructions, which includes the Guarantee Registration

Card.  The instructions are an integral part of the appliance and must, to comply with the current issue of the Gas Safety

(Installation and Use) Regulations, be handed to the user on completion of the installation.

T o  b e   l e f t   w i t h   t h e   u s e r

Instructions for Use

Installation and Servicing

G.C. No. 32- 047- 05

REGISTER YOUR GLOW-WORM APPLIANCE

FOR 1ST YEAR GUARANTEE PROTECTION

CALL 0208 247 9857

Thank you for installing a new Glow-worm appliance in your home.

Glow-worm appliances' are manufactured to the very highest standard so we are pleased to offer our customers'

a Comprehensive First Year Guarantee.

In the center pages are to be found your Guarantee Registration Card, which we recommend you complete and

return as soon as possible.

If this card is missing you can obtain a copy or record your registration by telephoning the Heatcall Customer

Service number 01773 828100.

Our Guarantee gives you peace of mind plus valuable protection against breakdown by covering the cost of:

9418

Содержание Miami GF

Страница 1: ... must to comply with the current issue of the Gas Safety Installation and Use Regulations be handed to the user on completion of the installation To b e l e f t w i t h t h e u s e r Instructions for Use Installation and Servicing G C No 32 047 05 REGISTER YOUR GLOW WORM APPLIANCE FOR 1ST YEAR GUARANTEE PROTECTION CALL 0208 247 9857 Thank you for installing a new Glow worm appliance in your home G...

Страница 2: ...ate RADIANTS After handling wash hands thoroughly INSULATION PADS CERAMIC FIBRE GLASSYARN MINERAL WOOL These can cause irritation to skin eyes and the respiratory tract If you have a history of skin complaint you may be susceptible to irritation High dust levels are usual only if the material is broken Normal handling should not cause discomfort but follow normal good hygiene and wash your hands b...

Страница 3: ... the protection of young children the elderly and the infirm Such a guard is also recommended for the protection of pet animals Although this fire conforms to all the applicable standards it is a heating appliance and certain parts of its surface will become hot Note The guard supplied with the fire acts as a fireguard conformingtoBS1945 1971andsatisfiestheHeatingAppliance Fireguard Safety Regulat...

Страница 4: ...less the control knob is held down at the ignition position If for any reason the flames go out when the fire is hot or if the fire is turned off when hot always wait at least three minutes before attempting to relight To light the fire The control is shown in diagram 2 Depress the control knob and turn anticlockwise towards the 1 IGN position A spark should be generated at the pilot while turning...

Страница 5: ... the upper and lower locating pins See diagram 4 Liftupthecentreradiantfromthebottomandwithdrawforwards Move the other radiants to the centre and remove in a similar way See diagram 5 To replace insert the top of the radiant first then the bottom Lower into position The back of the radiant should rest against the rear ribs of the metal fire box and the bottom front edge of the radiant should be be...

Страница 6: ...accordancewiththecurrenteditionoftheGasSafety Installation and Use Regulations Failure to install the appliance correctly could lead to prosecution The Council for the Registration of Gas Installers CORGI requires its members to work to recognised standards IntheUnitedKingdomtheinstallationmustalsobeinaccordance with All the relevant parts of local regulations All relevant codes of practice Therel...

Страница 7: ...mm Height Max 610mm Min 525mm Though the total height of the closure plate will accommodate a maximum opening height of 650mm heights above 610mm will leave the closure plate and sealing tape visible above the appliance The appliance must be mounted on a non combustible hearth N B conglomerate marble hearths are considered as non combustible The hearth must be at least 880mm wide x 300mm deep The ...

Страница 8: ...of 125mm dia flue pipe The flue must be clear of any obstruction and its base must be clear of debris Thefluemustbecompletelysealedsothatcombustionproducts do not come into contact with combustible materials outside the chimney The flue must serve only one fireplace Proprietary terminals must comply with BS 715 or BS 1289 Any terminal or termination must be positioned in accordance with BS 5440 Pa...

Страница 9: ... Preparation Stand the fire upright Remove the two transit screws from the top of the back panel see diagram 2 1 Remove the control knob by pulling clear of the gas tap spindle Remove the two case retaining screws located at the front of the case near the bottom See diagram 2 2 Lift the case up and forward to clear the rear top location and store in a safe place Remove the radiant pack Remove any ...

Страница 10: ...iently to allow satisfactory sealing Make sure that the rectangular air relief openings are fully within the fireplace opening The bottom of the appliance must be at least 50mm above any carpet or other floor covering To achieve this the bottom of the flue spigot opening must be at least 495mm above the finished floor covering 3 4 Flue Pull Check Check the flue pull with closure plate fitted by ap...

Страница 11: ...sureplatehasacut outforrearconnection Sealthegap between the cut out and the supply pipe Pressure check the installation pipework for gas soundness In the United Kingdom check in accordance with the current editionofBS6891 IntheRepublicofIrelandcheckinaccordance with the rules in force 4 4 Radiants Installation Fittheradiantsensuringthattheyrestagainstthehorizontalribs in the rear panel and that t...

Страница 12: ... wood transit strips secured with panel pins from the bottom of the wooden case sides Place the case over the engine Make sure that the channel near the top of the rear of the outer case locates fully into the wings of the engine back panel See diagram 6 1 Fit the control knob firmly on to the control spindle Refit the two case retaining screws at the front of the case near the bottom Listen for a...

Страница 13: ...isfactory Disconnect the appliance and advise the customer of the cause of failure 8 1 Final Review Make sure that the radiants and dress guard are securely in position Recheck the operation of the fire at all control positions Visually inspect the appliance Clean off any marks incurred during installation Advise the customer how to operate the fire Explain to the customer that the appliance has a...

Страница 14: ...n at the right side of the tap Remove the first screw securing the dust cage to the pilot unit burner bracket Carefully remove the dust cage and place aside Remove the second screw securing the pilot unit to the burner bracket Disconnect the electrode lead from below the pilot electrode Carefully remove the pilot unit together with the pilot pipe then disconnect the pipe from the pilot unit Replac...

Страница 15: ...lug back into the tap body Line up the slot in the plug with the mark previously made on the tap body Reassemble in the reverse order making sure that the components are correctly engaged Check the operation of the tap and piezo Make sure that the control knob with spindle is correctly turned to agree with the gas tap position before refitting the split pin 9 Servicing Parts Replacement KEY DESCRI...

Страница 16: ...de and place within 4mm of burner Operate igniter No spark Spark across gap Remove ignition lead from piezo unit and place screwdriver between applaince chassis and piezo tag leaving a 4mm gap between blade and tag Operate igniter No spark Spark No spark Renew ignition lead Renew piezo unit Reassemble ignition system and check ignition is satisfactory Renew Flue Blockage Safety Device Spark no ign...