Страница 1: ...To b e l e f t w i t h t h e u s e r Installation and Instructions for Use Outdoor Sensor www glow worm co uk...
Страница 2: ...rrect equipment for their needs that it is installed commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropr...
Страница 3: ...achieving an additional level of efficiency This control compensates for the outside temperature by modulating the lower radiator temperatures in warmer weather and higher radiator temperatures in col...
Страница 4: ...accept no liability in case of damage due to the non compliance of these instructions General Information Application The outdoor sensor controls the heating demand for the appliance which is dependan...
Страница 5: ...outdoor sensor is tested and certificated for safety and performance It is therefore important that no alteration is made to the outdoor sensor without permission in writing from Glow worm Any altera...
Страница 6: ...ion of this outdoor sensor must be carried out by a competent person in accordance the rules in force in the countries of destination Manufacturer s instructions must not be taken as overriding statut...
Страница 7: ...xternal North North West facing wall of the house For optimal reading of the outdoor temperature the device should be placed about 2 3 up the wall for buildings of 3 floors or less For higher building...
Страница 8: ...E W S N 1m 2 3 1 3 1m 1m 1m 1 2 3 4 1 2 3 1 3 OUTDOOR SENSOR POSITION For buildings higher than three floors OUTDOOR SENSOR POSITION For buildings three floors or less OUTDOOR SENSOR POSITION For bui...
Страница 9: ...G GLAND BACK BOX A Installation Diagram 3 Diagram 4 BACK BOX Refer to diagram 3 Remove the front cover seal and electrical sealing gland Choose the location of the outdoor sensor refer to page 6 Fit t...
Страница 10: ...iler refer to the literature supplied with your boiler for location and access Refer to diagram 5 thread the cable through the electrical sealing gland Connect the cable to the electrical connection p...
Страница 11: ...www glow worm co uk 11 OTC 1 and OTC 2 A Installation Diagram 6 13683...
Страница 12: ...www glow worm co uk 12 COVER SEAL A Installation Diagram 8 13669 Refer to diagram 8 fit and secure the seal and cover Diagram 7 14819 Connection at X41 on main PCB EDGE CONNECTOR...
Страница 13: ...ro or Glow worm Climastat is fitted please refer to section C to configure the outdoor sensor Glow worm Climapro Glow worm Climastat Configuration of the outdoor sensor is achieved through the Applian...
Страница 14: ...azing loft insulation and cavity wall insulation Method with example The following example describes the process The temperatures quoted should be substituted with real values to find the required hea...
Страница 15: ...nning screen is displayed Press and hold the mode button When the screen is lit orange and displays 0 release the mode button Plot these two points onto the chart They intersect the gradient curve lab...
Страница 16: ...played the heating part load for the appliance it will be different for various kW output boilers For example this could be 18 38 Using the domestic hot water button scroll through until d45 is shown...
Страница 17: ...B Configuring the Outdoor Sensor 50 60 70 80 90 30 40 9 0 1 3 7 4 2 5 6 8 20 Default curve Heating flow temperature C Minimum outdoor temperature C Factory default room temperature setpoint for weath...
Страница 18: ...ions it may be necessary to have a lower or higher ambient room temperature the adjustment is made in terms of an offset value which is entered into the appliance via diagnostic menu d 46 Refer to the...
Страница 19: ...ks of information d0 in the lower part of the screen in small text In the top centre of the screen where the pressure or temperature is normally shown is displayed the heating part load for the applia...
Страница 20: ...eased via diagnostic menu d 46 D 46 provides a means to offset from the default 20 C room set point For example to increase the target room temperature to 22 C set d 46 to the value 2 Range of value d...
Страница 21: ...ion and cavity wall insulation Method with example The following example describes the process The temperatures quoted should be substituted with real values to find the required heating curve 1 Selec...
Страница 22: ...limastat controls Adjusting Room Ambient With the heating curve correctly setup for your specific region the room temperature can be adjusted This is achieved by increasing or decreasing the setpoint...
Страница 23: ...with external Glow worm Climapro or Climastat controls 50 60 70 80 90 30 40 4 0 2 0 6 1 2 3 1 5 1 2 2 5 3 5 20 Outdoor temperature C Heating flow temperature C Default curve Factory default room temp...
Страница 24: ...Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions Glow worm Nottingham Road Belper Derbyshire DE56 1JT 0020040798 04 08 09...