WARNINGS AND CONTRAINDICATIONS 

Mandatory behavior 

For  maximum  safety,  the  device  must  be  used  respecting  the  rules  and  the 
limitations indicated by the user manual. 
The manufacturer declines any responsibility due to a different use from what it is 
indicated in this manual.  
No part of this manual (texts and/or photos) may be reproduced by electronic or 
mechanical means without the prior written authorization of the manufacturer. 
If  the  package,  the  cable  or  the  connector  of  the  power  supply  show  signs  of 
wear or damage, replace it instantly.  
The device should be connected to the mains by its power supply. Before starting 
the  treatment,  make  sure  that  the  power  system  specifications  comply  with  the 
directives in force in your country. Make sure that  the power supply will be easily 
unplugged. 
Do not modify the device. 

Warnings before the use 

DANGER OF BURNS:  an improper use of the system may cause scalds or burns to 
the treated subject.  
Do  not  use  Rf  Beauty  6000  Med  simultaneously  with  other  electronic  devices, 
especially  if  they  maintain  vital  functions.  Read  the  tables  at  the  end  of  the 
present  manual  for  a  correct  use  of  Rf  Beauty  6000  Med.  If  you  have  to  use  the 
device near or upon other devices, pay attention to how it is working. 
It is recommended to read carefully the entire operating manual before using the 
device; keep this manual carefully. 
Checking  the  integrity  of  the  device  before  each  use  is  a  fundamental 
requirement to perform the therapy. Do not use the unit if the cables or the buttons 
are defective or malfunctioning. 
Do not use flammable materials while using the device. 
The device should be kept out of the reach of children. 
During  the  treatment,  remove  metal  objects  e.g.  bracelets,  necklaces,  piercings, 
etc. 
Before starting the treatment, make sure that the skin of the patient is  clean and 
dry. 

Warnings during the use 

While  using  the  device,  make  sure  that  handpieces  are  well  covered  with 
conductive  cream  and  that  their  surface  is  completely  kept  in  contact  with  the 
skin of the patient. 
Adjust the emission power according to the individual tolerance to heat. 
Do not let the handpiece stay still during the emission, as it may cause burns. 

Содержание RF CLINIC PRO

Страница 1: ......

Страница 2: ...2 Rev 12 18 of 12 12 18...

Страница 3: ...PRODUCT WE REMAIN AT YOUR DISPOSAL FOR ANY ASSISTANCE OR ADVICE YOU MAY NEED Devices for radio frequency RF Clinic Pro are produced and distributed by DOMINO SRL Via Vittorio Veneto 52 31013 Codogn TV...

Страница 4: ...S 7 Accessories 8 Device 8 Interface and controls 9 Display 9 ALARMS 10 WARNINGS AND CONTRAINDICATIONS 11 Mandatory behavior 11 Warnings before the use 11 Warnings during the use 11 Side effects 12 Co...

Страница 5: ...pply unit Model GlobTek GTM91099 6024 6 0 T2 PRI 100 240V 50 60Hz SEC 18Vd c 3 3A Max Polarity Supplied accessories Rf Clinic 100 handpiece The Rf Clinic 100 handpiece is bipolar and has two spheres I...

Страница 6: ...ntegrity of the device and its accessories INTENDED USE The product has an estimated usable life of 5 years It is advisable to return the device to the producer and or authorized center to perform sec...

Страница 7: ...ease contact our customer care to replace the battery pack LABELING AND SYMBOLS WEEE symbol Waste of Electrical and Electronic Equipment Recycling symbol The WEEE symbol used for this product indicate...

Страница 8: ...bus conductive cream label Do not ingest Hypoallergenic product The product can only be used externally on intact skin The product is disposable To treat more patients use the specific measuring cup o...

Страница 9: ...in the menu left arrow to go back to the previous screen 3 On off pause button 4 Asterisk button to edit treatment duration Display 1 Indicates the name of the selected program 2 Indicates the percent...

Страница 10: ...the led turns on check the connections between the cables and the electrodes If the led is still on contact the service centers Power level indicator Acoustic signals During the use the device emits a...

Страница 11: ...imultaneously with other electronic devices especially if they maintain vital functions Read the tables at the end of the present manual for a correct use of Rf Beauty 6000 Med If you have to use the...

Страница 12: ...ty hypoesthesic areas particularly obese subjects acute inflammatory diseases MAINTENANCE AND CLEANING Device and accessories In case of any real or alleged malfunctioning neither tamper with the devi...

Страница 13: ...he fire but dispose of the product in the specialized centers and respecting the regulations in force in your country When the product has to be disposed of the user can give it back to the retailer w...

Страница 14: ...use the right left direction buttons to move to the next letter A the end press Ok to save the program It is possible to save up to 30 programs Settings This menu provides access to the editing of so...

Страница 15: ...om 60 to 90 Scars 100 12 from 60 to 90 Body pimples 100 18 from 60 to 90 Skin restructure 100 20 from 60 to 90 Skin smoothing 100 20 from 60 to 90 Firming 100 14 from 60 to 90 Massage 100 20 from 60 t...

Страница 16: ...t less than six months The first results are normally visible after every treatment and they are mainly due to the action on the local micro circulation After 10 sessions skin compactness starts depen...

Страница 17: ...of diminished or slowed cell renewal connected with old age Scars Same operation principle but specifically designed for applications on scar tissue Moreover the energy emitted by RF Clinic causes the...

Страница 18: ...r original packages 2 The warranty is valid only when the receipt or invoice of the product indicating the purchase date of the product is enclosed 3 The repair work shall have no effect on the origin...

Страница 19: ...19 Rev 12 18 of 12 12 18...

Страница 20: ...20 Rev 12 18 of 12 12 18...

Отзывы: