9.1.17.3 Full Suspended
In the full suspended state, the tracker and transmitter are suspended and cannot be used.
9.1.17.4 Power Management State Changes
Power management state changes can be set with the Power Management Set Power State API. Based on the user’s
implementation and power architecture, the ST150M’s power state can be directed to the appropriate state.
9.1.18 Temperature Notifications
Temperature notification events can be configured for high/low temperatures on the ASIC and MCU. URCs for these events
can be enabled for visibility from external interfaces.
9.1.19 DATA LOGGING
Data logging includes logging of GPS track positions, OTA message metadata, and controllable diagnostic logging from the
device’s Unified API modules.
9.1.19.1 GPS Position Logging
GPS Position Logging can optionally be disabled to prevent sensitive location data from persisting on the device.
9.1.19.2 OTA Metadata Logging
OTA Metadata Logging logs information about all OTA messages that enter the Transmit Queue (See Transmit Queue section
for logging details).
9.1.19.3 Diagnostic Logging
Diagnostic logging can be used to enable various levels of debug verbosity from each UAPI module, and have those logs
save to flash for retrieval later. This can be very useful for troubleshooting an issue, and being able to review logs afterthe-fact
via the Globalstar Mobile App.
9.1.20 BLE SETTINGS
9.1.20.1 Advertising Prefix
The advertised name of the device can have up to 3 proceeding characters customized with the Advertising Prefix setting
9.1.20.2 BLE Power
The transmit BLE power can be adjusted with the BLE Power setting
9.1.20.3 BLE Advertising Interval
The BLE Advertising Interval can be customized. The advertising interval may be disrupted or delayed due to BLE
connections or Smart One Sensor operations (see Smart One Sensor Service Section)
9.1.20.4 BLE Config Service Advertising Enabled
The BLE Config Service Advertising Enabled controls whether or not the config service, Nordic DFU (firmware update)
service, and ASIC DFU services are advertised.
See BLE Configuration Service and Interfaces section for additional details
9.1.20.5 Nordic UART Service (NUS) Enabled
Nordic UART Service is essentially a UART over BLE, and can be optionally enabled or disabled. See BLE Configuration
Service and Interfaces section for additional details