37
ST150M User Manual
Confidential & Proprietary Information
9150-0125-01 R-1
• To receive all Accelerometer event notifications, the valid command to activate all notifications AT+ANSF =511
• To receive all Accelerometer event notifications over configuration service, the valid command to activate all notifications
AT+AANSF = 511.
• AT+ANSF = 512 or greater will return ERROR.
7.10 POWER MANAGEMENT EVENT NOTIFICATION SETTINGS
Supported Power Management Event notifications code < PowerManagementNotifyFlags>
• POWER_NOTIFY_MCU_RESET = 1
• POWER_NOTIFY_TX_ASIC_RESET = 2
• POWER_NOTIFY_FLAGS_POWER_STATE_CHANGED = 4
• POWER_NOTIFY_FLAGS_TEMP_ALERT = 8
• POWER_NOTIFY_FUEL_GAUGE_ERROR = 16
• POWER_NOTIFY_TX_TEMP_THRESH_ALERT = 32
• POWER_NOTIFY_VOLT_ALERT = 64
7.10.1 SET POWER MANAGEMENT NOTIFY FLAGS VIA NUS, UART.
AT+PNSF = < PowerManagementNotifyFlags>
7.10.2 READ POWER MANAGEMENT NOTIFY FLAGS VIA NUS, UART.
AT+PNSF? Response
+ PNSF: < PowerManagementNotifyFlags >
7.10.3 SET POWER MANAGEMENT NOTIFY FLAGS VIA CONFIGURATION SERVICE
AT+PANSF = < PowerManagementNotifyFlags >
7.10.4 READ POWER MANAGEMENT NOTIFY FLAGS VIA CONFIGURATION SERVICE
AT+PANSF?
Response
+ PNSF: < PowerManagementNotifyFlags >
Example:
• To receive ASIC RESET and POWER STATE CHANGE event notification, the valid command to activate notification
AT+PNSF = 6.
• To receive all Power Management event notifications, the valid command to activate all notifications AT+PNSF = 127.
• To receive all Power Management notifications over configuration service, the valid command to activate all notifications
AT+PANSF = 127.
• AT+PNSF = 128 will return ERROR.