Page 54
SmartOne C User Manual
Confidential & Proprietary Information
9100-0410-01 R2.4
CONTACT SERVICE PROVIDER MESSAGE
The SmartOne will send a Contact Service Provider message when an internal fault is detected. The SmartOne will
send one such message upon the detection of an internal fault. It will then attempt to continue to operate normally.
The SmartOne will not send another Contact Service Provider message unless the fault is determined to have
cleared, and then determined to have come back again.
ACCUMULATE/COUNT MESSAGE
The Accumulate/Count message is used to report the accumulation of time that an input is in a specified state as
defined by the user, the accumulation of time that the device is in a State of Vibration, and/or the total transitions of
the Inputs, as configured by the user. The message is transmitted either at a pre-set interval, at a point where any
of the accumulation or count registers reach multiples as programmed by the user, just before rollover of any count/
accumulate register, or all of the above. Appendix J has an example of a decoded Accumulate/Count message.
BYTE #
VARIABLE
BITS
DESCRIPTION
0
TYPE FIELD
2
Bit (1:0) = 3 Non Standard message type:
0
SUBTYPE
6
Bit (7:2) = 24 Accumulate/Count message..
1, 2
ACCUMULATED INPUT 1
16
Accumulated time that Input 1 has been in its undesired state with a resolution of
10 minutes. For example: 1 hour would be represented as a value of 6, 2 hours as
a value of 12, etc. This resolution results in a rollover rate of a total time accumu-
lation of approximately 1.25 years. (OxFFFF means that Input 1 Accumulate has
been turned off)
3, 4
ACCUMULATED INPUT 2
16
Accumulated time that Input 2 has been in its undesired state with a resolution of
10 minutes. For example: 1 hour would be represented as a value of 6, 2 hours as
a value of 12, etc. This resolution results in a rollover rate of a total time accumu-
lation of approximately 1.25 years. (OxFFFF means that Input 2 Accumulate has
been turned off)
5, 6
ACCUMULATED VIBRATION
16
Accumulated time that the SmartOne has been in a State of Vibration with a
resolution of 10 minutes. For example: 1 hour would be represented as a value of
6, 2 hours as a value of 12, etc. This resolution results in a rollover rate of a total
time accumulation of approximately 1.25 years. (OxFFFF means that Accumulated
Vibration has been turned off)
7
INPUT 1 COUNT
8
The total number of openings or closings of input 1 as selected by the user. (OxFF
means that Input 1 Accumulate has been turned off)
8
INPUT 2 COUNT
8
The total number of openings or closings of input 2 as selected by the user. (OxFF
means that Input 2 Accumulate has been turned off)