MODEL YEAR 2016
N…102 Hy
N…102
WORKSHOP MANUAL
WORKSHOP MANUAL
1 / 1
7.6.
0
STARTER RELAY
OPERATION CHECK
General informations:
---
Related topics:
---
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
18
17
16
15
14
13
12
11
20
19
9
8
7
6
5
4
3
2
1
10
1
2
Remove the cap of the sparking plug (or plugs),
since the safety systems that normally prevent
accidental starting of the engine are cut out
when the checking procedure is carried out.
To do this requires:
– engaging the parking brake;
– disengaging the blade;
– the key in the «ON» position.
Disconnect the connector (1).
In making a bridge between the terminals 11 and 4 of
the wiring connector (1), the click of the relay bobbin
should be heard and the starter motor should come
into action.
only with B&S engines
If the relay clicks but the starter motor does not
go, make a bridge (2) with a large section cable
(5 mm
2
) between the power contacts of the relay.
If the starter motor comes into operation, look for
the fault within the relay or replace it. Otherwise,
check the starter motor together with its wiring.
BACK