NETWORK FUNCTIONS 

 

Complete list of functions 

For communications verification the main functions are highlighted in

 bold 

 

1 Review Historic Log 
1-1 Display Historic Log 

1-3 Clear Historic Log 
1-5 Read/Clear Autostart Count 
 
3 Zones - Disable & Assign 
3-1 Disable Zones 
3-2 Assign Sounder Groups to Zones 
3-3 Assign I/O Groups to Zones 
3-4 Assign Zone to Device 
3-5 Zone Sounder Delay Set-up 
 
4 Sounders - Disable & Assign 
4-1 Sounder Configuration 
4-2 Configure Sounder Groups 
4-3 Disable Sounders 
4-4 Assign Sounder Group to Device 
4-5 Inhibit Sounders for Device 
4-6 Sounder Delay Set-up 
4-7 Override Sounder Delays 
 
5 Input/Output - Disable & Assign 
5-1 Configure I/O Groups 
5-2 Select Fault I/O Group 
5-3 Assign I/O Group to Device 
5-4 Inhibit I/O for Device 
5-5 I/O Unit Action upon Evacuate 
5-6 I/O Unit Delay or Immediate 
5-7 I/O Delay Set-up 
 
6 Device Set-up 
6-1 General 
6-1-1 Disable Loops 
6-1-2 Device Disable 
6-1-3 Set Selective Disablement 
6-1-4 Set Device Reporting Details 
6-1-5 Set Immediate Evacuate for Device 
6-1-6 Device Activation Overrides Delays 
6-1-7 Inhibit Auxiliary Relays 
6-1-8 Global Behaviour Set-up 
6-1-9 Configure Timed Behaviour 
6-3 Device Specific - Functions only available for panels 
programmed to ZEOS Protocol 
6-3-1 Select Device Behaviour  Mode 
6-3-2 Flashing LEDs On/Off 
6-3-3 Disable Specific Flashing Leds 
6-3-4 Re-calibrate All Devices 
6-3-5 Check for Devices Needing Service 

6-3-6 Read Data Stored in Device 
6-3-7 Write Data Stored in Device 
6-3-8 Select Device Smoke Sensitivity 
6-3-9 Select Device Heat Grade 
6-4 Automatic Address Setting 
6-4-1 Activate ASET Mode 
6-4-2 Clear Loop 
6-4-3 Clear Device 
 

7 Monitor Device Counts & Test 
7-1 Device Count, Type & Value 

7-2 Test Sounders 
7-3 Sounders on Test Activation 
7-4 Test Zones 
7-6 Light LED on device 
 

8 General 
8-1 Time/Date & Timers 
8-1-1 Set Date & Time 

8-1-2 Define Day & Night 
8-1-3 Delays Off at Night 
8-1-4 Configure Evacuate Timer 
8-1-5 Device Starts Evacuate Timer 
8-1-7 Configure Extended Delays 
8-1-8 Configure Disablement Timer 
8-2 Special Features Set-up 
8-2-1 Two Devices to Evacuate 
8-2-2 Call Points to Evacuate 

8-3 Memory - BEWARE, ENGINEERS ONLY 

8-3-1 Checksums 

8-3-2 Clear Non-Volatile RAM 

8-3-3 Calculate Customer Flash Checksum 
8-3-4 Calculate Program Flash Checksum 

8-4 Other Features 
8-4-1 Active/Installation Mode 

8-4-4 Set User Access Code 
8-4-5 Set User Functions 
8-4-6 Select Language 
8-4-8 Set Installer Access Code 
8-4-9 Set Master Access Code 

8-5 Network Configuration 
8-5-1 Configure Panel Number 
8-5-2 Known Panels 
8-5-3 Installation Status 
8-5-4 Broadcast Configuration 
8-5-5 Communication Channels 
8-5-6 BMS Setup 
8-9 Version Information 

 
 

 

 

18 

Содержание CHAMELEON GEKKO

Страница 1: ...RODUCTION 8 Mains Power connection 8 Control Panels and Repeaters Location 8 CHAMELEON NETWORK TOPOLOGY 9 Closed Loop Network example 9 Open Loop Network example 10 Mesh Network example 10 Extended di...

Страница 2: ...23 Wait 2 minutes for network recognition 23 Change system to Active Mode 23 Verify remote devices on the installation 24 TROUBLESHOOTING 24 COMMUNICATION FAILURE 24 RX connection break on Panel 2 dis...

Страница 3: ...n independent SYSTEM EVENT LOG rolling 10000 entries Customer configuration can be broadcasted to all panels over the network High Immunity in high latency network connections Configuration mismatch d...

Страница 4: ...e Optic Link A connection method for data that uses light instead of electrical signals The connection is made using fibre optic cables rather than copper electrical cables Fibre optic signals can tra...

Страница 5: ...Global Fire Equipment globalfire pt ma_chmcomm_01_010001_en_191121 IDENTIFYING COMPONENTS and COMMUNICATIONS INSIDE GEKKO INSIDE OCTO 5...

Страница 6: ...Global Fire Equipment globalfire pt ma_chmcomm_01_010001_en_191121 NOTE ALL CHANNELS CHx SHOULD BE CONNECTED THROUGH INTERFACES 6...

Страница 7: ...S422 P2P S FIBRE OPTIC INTERFACE INT FO P2P D INT FO P2P S INTERFACE FOR TCP IP COMMUNICATION INT TCP IP P2P MIXED INTERFACE INT RS422 P2P MIX FO All Interfaces should be connected to panels using the...

Страница 8: ...positions of the PCBs before powering up the system ELECTRO STATIC SENSITIVE DEVICES ESD TAKE SUITABLE ESD PRECAUTIONS WHEN REMOVING OR INSTALLING PRINTED CIRCUIT BOARDS WARNING observe ESD precautio...

Страница 9: ...ations failure In the case of unused connectors network derivations and mesh wired topologies can be used Nevertheless the Closed Loop Example is the most commonly used and recommended Closed Loop Net...

Страница 10: ...fire pt ma_chmcomm_01_010001_en_191121 Open Loop Network example NOTE THIS IS NOT RECOMMENDED IT DOES NOT HAVE COMMUNICATIONS REDUNDANCY Mesh Network example NOTE COMMUNICATIONS HIGHLY REDUNDANT DIFFE...

Страница 11: ...splay In this situation by applying a Chameleon Display you will have an extension of the Fascia with a maximum of two Please do not confuse with Network Addressed Chameleon Repeater panel RS422 FIBRE...

Страница 12: ...ions or short circuits by creating a bi directional communications flow If the panel loses communications with other elements of the network it will have the option via opposite path RS422 422 may be...

Страница 13: ...wo panels with two redundant independent Fibre network paths This will use 4 flat cables two per panel and two for each physical connection Connections are made using fibre optic cables instead of cop...

Страница 14: ...CH1 CH2 CH1 CH2 CH1 TX2 RX1 TX2 RX1 TX2 RX1 RX2 RX1 RX2 TX1 RX2 TX1 If more panels are connected the same scheme can be applied Continue to connect CH2 of one Repeater to CH1 of the next Repeater fol...

Страница 15: ...the Panel On the CHAMELEON REP the flat cable interface connections are different from the GEKKO as shown below GEKKO connections are made on the front of PCB and on CHAMELEON REPEATER are made on th...

Страница 16: ...chnical support INT TCP IP P2P This interface allows a Peer to Peer connection It is necessary one Interface for each physical link acting as a serial point to point link NOTE This is not a double int...

Страница 17: ...obtained directly from the auxiliary power supply output of neighbour panel Apply power to the repeater If after a few seconds upon completion of the initialization phase the LCD display shows the me...

Страница 18: ...able for panels programmed to ZEOS Protocol 6 3 1 Select Device Behaviour Mode 6 3 2 Flashing LEDs On Off 6 3 3 Disable Specific Flashing Leds 6 3 4 Re calibrate All Devices 6 3 5 Check for Devices Ne...

Страница 19: ...system is not in fault nor fire Press ENTER to skip an entry and after each entry It is important to set the date and time because it is used in the event logging and may also be used to change the de...

Страница 20: ...allows changing the Panel Network Number address This should be unique in the network NOTE The Chameleon Rep will need to set an unique Panel Network Number 8 5 2 Known Panels This function will show...

Страница 21: ...on port 01 to 64 ODYSSEY not applied CH2 working as an ODYSSEY port with the specified PANEL ADDRESS XX not applied SHORT MSG 1 CH2 working as short text serial port DECT no fault B Alarm V PreAlarm 2...

Страница 22: ...nge on each panel 8 4 1 menu If any fault is triggered after reset please acknowledge by pressing BUZZER SILENCE button If the triggered fault is related with mismatch configuration or communications...

Страница 23: ...panels and all communications channels are displaying OK on the 8 5 5 Menu Before proceeding with the commissioning the communications path should now be closed creating a redundant two way messages...

Страница 24: ...only reported by RX receiving channel evaluation Go to menu 8 5 5 Communication Channels to check connections RX connection break on Panel 2 disconnect RX1 or RX2 Panel 2 is no longer receiving in on...

Страница 25: ...F FAULTS 0001 PANEL 01 COMMUNICATION FAILURE TOTAL NUMBER OF FAULTS 0001 PANEL 01 COMMUNICATION FAILURE TOTAL NUMBER OF FAULTS 0001 TX2 connection break on Panel 2 Panel 3 is no longer receiving in on...

Страница 26: ...ers have not All panels will trigger Panel Configuration Mismatch on Panel 1 Panel 1 will trigger the fault mentioning all other panels on the queue Panel 1 Panel 2 Panel 3 PANEL 02 PANEL CONFIGURATIO...

Страница 27: ...r the fault mentioning all other panels on the queue After an USB Config Update the menu 8 5 4 Broadcast Configuration should be executed in order to copy same configuration to all network panels The...

Страница 28: ...ation Mode Panel 1 TX2 is not properly wired Meaning that with an open loop Panel 1 is able to see Panel 2 and Panel 3 But Panel 2 and 3 are unable to see Panel 1 on the network Panel 1 is missing Pan...

Страница 29: ...2 Known Panels Known 03 01 02 03 Menu 8 5 5 Communications Channels CH1 CH2 CH3 OK OK Menu 8 5 5 Communications Channels CH1 CH2 CH3 OK Menu 8 5 5 Communications Channels CH1 CH2 CH3 OK OK GLOBAL FIRE...

Отзывы: