background image

IMPORTANT:  Even if you have the Pro Series 1000
backup sump pump system installed by someone
else,  you  must  read  and  follow  the  safety
information contained in this manual.  Failure to
do  so  could  result  in  property damage,  serious
injury, or death.

Battery Backup

Sump Pump

System

Instruction

Manual & Safety

Warnings

Table of Contents

Important Safety Warnings and
Instructions

Electrical precautions

1

Battery preparation

1

Battery precautions

1

Introduction

Items included in system

2

Additional items needed

2

Replacement parts list

2

System specifications

2

Pump & Pipe 
Installation Instructions

Installation options

3

Direct discharge to outside

4

Connection to existing discharge

5

Direct discharge for narrow sumps

6

Connection to existing discharge 
for narrow sumps

7

Battery Instructions

8

Control Unit Connections

Mounting the control unit

9

Positioning the float switch

9

Connecting the pump

9

Installing the battery fluid sensor

9

Connecting the battery

9

Connecting the charger

9

Understanding the Warning
Lights and Alarms

Silencing the alarm during 
an emergency

10

Power alarm

10

Fluid low alarm

10

Refilling the battery

10,11

Pump activated alarm

11

Replacing the pump

11,12

System operating

12

Cleaning battery terminals

12,13

Replacing the battery

13

Testing the System

Testing the pump

14

Testing the float switch

14

Parts & Service Information

Technical support

14

Troubleshooting Guide

14

Warranty

15

Other Products

15

Содержание PHCC-1000 Pro Series

Страница 1: ...Direct discharge to outside 4 Connection to existing discharge 5 Direct discharge for narrow sumps 6 Connection to existing discharge for narrow sumps 7 Battery Instructions 8 Control Unit Connections...

Страница 2: ...EN To help reduce these risks observe the following precautions Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of f...

Страница 3: ...may not be compatible with this system Glentronics cannot guarantee the compatibility of other brands of batteries The use of a Pro Series battery is HIGHLY recommended 1 rigid PVC pipe and fittings P...

Страница 4: ...ove the main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so the backup pump and the main pump do not touch each other Select the installation metho...

Страница 5: ...xterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe w...

Страница 6: ...prevent the pump from operating 4 If there is no check valve on the discharge pipe of the main AC pump one must be installed at this time Cut the discharge pipe approximately one 1 foot above the flo...

Страница 7: ...pipe and the details of each installation will vary Using sound plumbing practices try to route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will redu...

Страница 8: ...e and cement it to the 1 pipe adapter then screw the adapter into the pump 5 Install a check valve on the top of the PVC pipe attached to the Pro Series pump Make sure it is installed with the arrow p...

Страница 9: ...tions on page 1 NOTE PRO SERIES BATTERIES NOW COME IN TWO CONFIGURATIONS THE TOPS OF THE BATTERIES LOOK DIFFERENT AND THE DIRECTIONS FOR FILLING THE BATTERIES AND CONNECTING THE FLUID SENSOR WILL VARY...

Страница 10: ...e sump Position the unit in a well ventilated area Do not place anything on top of the battery Diagram F 1 Mounting the control unit a Thread one plastic wire tie through the two mounting brackets on...

Страница 11: ...ump alarms slide the Audible Alarm switch to OFF The AC power and or the Pump light will remain on but the audible alarm will not sound When the emergency has ended slide the switch to the ON position...

Страница 12: ...tes the float switch the pump will begin pumping and the Pump was activated light and alarm will turn on The alarm stays on to alert you to the fact that the standby system was used to empty water fro...

Страница 13: ...battery alarm goes on while the pump is running and the power is out you will have a minimum of one half 1 2 hour of continuous pumping time to replace the battery In most cases the pump does not run...

Страница 14: ...ttery box and place the new battery in the box Fill the battery following the instructions on page 8 6 Clean any corrosion off of the ring connectors on the ends of the battery wires Use a stiff brush...

Страница 15: ...attery fluid levels PARTS SERVICE INFORMATION You can receive technical support or order parts by calling Glentronics Inc at 800 991 0466 option 3 or by visiting the Pro Series website at www stopfloo...

Страница 16: ...SS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THE CUSTOMER S EXCLUSIVE REMEDY FOR BREACH OF THIS WARRANTY OR OF ANY IMPLIED WARRANTY NO...

Отзывы: