background image

Specifications

1/3 HP Model SP-33T

1/2 HP Model SP-50T

GPH @ 0’

3700

3900

GPH @ 10’

2800

3100

Pump diameter

9.5”

9.5”

Volts

115V, 60Hz

115V, 60Hz

Amps

4.2

5.5

Important Safety Instructions

SAVE THESE INSTRUCTIONS. 

This manual contains important SAFETY WARNINGS and

OPERATING INSTRUCTIONS for the Basement Watchdog pumps.  You will need to refer to
it before attempting any installation or maintenance.  

ALWAYS

keep these instructions with the unit so that they will be easily accessible.

Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death. 

ALWAYS

disconnect the pump from the power source before servicing or making

adjustments.

NEVER

handle the pump or motor with wet hands or when standing on a wet or damp

surface while the pump is plugged into the power source.

MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE.

This pump is

wired with a 3-prong grounded plug.  To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle.  If you have a 2-
prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.

NEVER

bypass grounding wires or remove the ground prong from the plug. 

DO NOT

use an extension cord.  The electrical outlet should be within the length of the

pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.

DO

protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.

Avoid kinking the cord.

MAKE SURE 

the supply circuit has a dedicated fuse or circuit breaker rated to handle

the power requirements noted on the nameplate of the pump.

DO NOT

use the power cord or strain relief to carry the pump.  Use the pump handle.

DO NOT

operate the pump if it has been damaged in any way.

DO NOT

use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.

This pump is for ground water use only.

DO NOT

use in continuous duty applications such as fountain ponds.  This pump is rated

for intermittent use only.  

DO NOT

disassemble the pump or float switch.  When service is required, contact

Glentronics technical support at 800-991-0466, option 3.  Return the product to the
manufacturer for any repairs at the following address:

Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069

Risk of electric shock. To reduce this risk, observe the
following precautions

.

To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.

Basement Watchdog

Sump Pumps

Instruction Manual &

Safety Warnings

Items Included:

Pump with tether float switch

You may also need:

A 1-1/2” PVC pipe adapter to screw into the discharge hole near the 
bottom of the pump
1-1/2” rigid PVC pipe to connect to the existing plumbing
A check valve or rubber union
PVC pipe cleaner and cement
Wire ties or hose clamps

Models SP-33T and SP-50T

!

WARNING

!

CAUTION