Page
13
of
30
CARTRIDGE SETUP
For best results it is important to carefully setup the front panel dip switch (input
channel controls) for both channels of both inputs.
Most cartridge manufacturers supply information such as the recommended load
impedance and the recommended load capacitance. The Athens 2’s input should be
set to match these recommended figures.
IMPORTANT NOTE
: Input 1’s left and right channels should be setup identically and
input 2’s left and right channels should also be setup identically.
Available Controls
Each input has 3 sets of controls.
1)
G…Gain….this adjust the gain of the preamplifier
2)
Z…Impedance….this sets the input impedance
3)
C…Capacitance….this sets the input capacitance
First Remove The Anti-Tamper Screen
Before adjusting the setup dip switches the Anti-Tamper screen must be removed by
unscrewing the Anti-Tamper screw (this has a standard pozi drive head).
Anti-Tamper Screw