www.gdts.one
451905.66.07 · FD 9912
EN-5
DHW 300VD+
English
2.5 Temperature sensor
2.5.1 Temperature sensor installation
position
R1 Air inlet sensor
R3 Domestic hot water sensor
R5 Domestic hot water renewable sensor (optional)
R12 Defrost end sensor
R13 Renewable sensor (optional)
2.5.2 Measured values temperature sensor
Measured values NTC 10 sensor (R1, R3, R5, R12)
Measured values PT 1000 sensor (R13)
3
Storage and transport
3.1 General
The domestic hot water heat pump should always be stored
and transported packaged in an upright position, without being
filled with water. Short distances and a maximum incline of 45°
are permitted during careful transportation without accesso-
ries. Transportation along inclines of 45° is only permitted with
accessories (siehe Kap. 3.4 auf S. 6). Ambient temperatures be-
tween -20 and +60 °C are permissible during transport and
storage.
3.2 Fork lift (or lift truck) transport
The domestic hot water heat pump must remain mounted on
the pallet when being transported with a fork lift. The lifting
speed must be slow. Because of its high centre of mass, the do-
mestic hot water heat pump must be secured against toppling.
To prevent damage, the domestic hot water heat pump must
be lowered onto a level surface.
3.3 Manual transport (factory
default)
The wooden pallet can be used underneath the device for the
purpose of manual transportation. A second or third carrying
position can be created with the help of ropes or carrying slings
(these may be wrapped around the cylinder casing and at-
tached to the water pipe nipples). When transporting the heat
pump in this manner (or with a hand truck), do not, under any
circumstances, exceed the max. tilt angle of 45° (see illustra-
tion).
ATTENTION!
!!
The device cover cannot be used for carrying (the cover
cannot withstand significant forces)
NOTE
º
When tilting, edges and the display must be protected from
possible damage
Temperature in °C
-20 -15 -10
-5
0
5
10
NTC-10 in k
67.7
53.4
42.3
33.9
27.3
22.1
18.0
15
20
25
30
35
40
45
50
55
60
14.9
12.1
10.0
8.4
7.0
5.9
5.0
4.2
3.6
3.1
Temperature
in °C
-30 -20 -10 0
10 20 30 40 50
PT 1000 in k
0.88
2
0.02
2
0.96
1
1.00 1.03
9
1.07
8
1.11
7
1.15
5
1.19
4
60 70 80 90 100 110 120 130 140 150 160
1.23
2
1.27
1
1.30
9
1.34
7
1.38
5
1.42
3
1.46
1
1.49
8
1.53
6
1.57
3
1.61
1
45°
45°
max. 45°
Содержание DHW 300VD+
Страница 2: ......
Страница 46: ...EN 22 451905 66 07 FD 9912 www gdts one English DHW 300VD...