background image

Glastender, Inc. · North Michigan Road · Saginaw, MI · 48604-9780 

800.748.0423 · 989.752.4275 · Fax 800.838.0888 / 989.752.4444 · www.glastender.com

© 2006 Glastender, Inc. 

B

EER

 P

ANELS

 

I

NSTALLATION

 I

NSTRUCTIONS

Rev. 04-06-06 

BPIK-EY, Beer Pump Panel with Empty Keg Detector 

& Y Angle Bracket

Page 5

BPIK-E, Beer Pump Panel with Empty Keg Detector

Page 3

BPIK-Y, Beer Pump Panel with Y Angle Bracket

Page 4

BPIK, Beer Pump Panel

Page 2

BIK-EY, Beer Panel with Empty Keg Detector & 

Y Angle Bracket

Page 9

BIK-E, Beer Panel with Empty Keg Detector

Page 7

BIK-Y, Beer Panel with Y Angle Bracket

page 8

BIK, Beer Panel

Page 6

Page 1 of 9

Содержание BIK

Страница 1: ...06 BPIK EY Beer Pump Panel with Empty Keg Detector Y Angle Bracket Page 5 BPIK E Beer Pump Panel with Empty Keg Detector Page 3 BPIK Y Beer Pump Panel with Y Angle Bracket Page 4 BPIK Beer Pump Panel...

Страница 2: ...exhaust port connection F Use the CO2 line provided to exit the CO2 from the walk in cooler An extra tee is provided with each panel in case you want to join the exhaust lines of adjacent panels THE E...

Страница 3: ...the polyline G from the beer line set conduit to the side output port of each EKD 8 Approximately 6 feet of exhaust line H is provided for the exhaust port of each EKD Trim the exhaust line to length...

Страница 4: ...to the top output ports of each Y angle bracket 7 The CO2 exhaust port of each pump has been pre plumbed at the factory to create one CO2 exhaust port connection H Use the CO2 line provided to exit th...

Страница 5: ...ropriate EKD side output port using a black washer 8 Attach the polyline I from the beer line set conduit to the top output ports of each Y angle bracket 9 Approximately 6 feet of exhaust line J is pr...

Страница 6: ...yl beer line B is provided for the keg jumper line from each keg to its angle bracket C Trim clear line to size and attach one end to bottom of angle bracket and the other end to the keg tap 4 Approxi...

Страница 7: ...r the keg jumper line from each keg to its EKD Trim clear line to size and attach one end to bottom input port of the EKD and the other end to the keg tap 5 Approximately 9 feet of red air line D is p...

Страница 8: ...f Y angle bracket and the other end to the keg tap 4 Approximately 9 feet of red air line D is provided for the jumper line from each keg to its regulator E Trim red air line to size and attach one en...

Страница 9: ...e E is provided for the keg jumper line from each keg to its EKD Trim clear line to size and attach one end to the bottom input port of the EKD and the other end to the keg tap 6 Approximately 9 feet...

Отзывы: