GKOLED GKOFD05 Скачать руководство пользователя страница 1

Installation Guide

LED FLOOD LIGHT

Installation Guide

WARNING

— To prevent personal injury or product damage only licensed electricians should install.

— To avoid electric shock or component damage disconnect power before attempting installation or servicing.

— This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local electric codes and safety standards.

— Disconnect product and allow cooling prior to servicing.

— Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product malfunction.

— To prevent product malfunction and/or electrical shock this product must be properly grounded.

— This luminaire is designed to operate in ambient temperatures ranging from -40°C to 45°C.

— This product must be installed in accordance with the applicable installation code by a Person familiar with the construction and operation of the product and 

     the hazards involved.

— In 75°c supply conductors.

— Slipfitter Mounted with PHOTOCELL function elevation angle should not exceed 15 degrees

PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION

TROUBLESHOOTING 

1. 

to wiring directions.

2. 
3.  Be sure the photocell, if used, is functioning properly.

Universal voltage driver permits operation at 120V to 277VAC,
60 Hz except fixtures factory ordered with a 347V photocell (P3) 
or 480V photocell (P4) or 120-277V photocell(P0).

PHOTOCELL INSTALLATION

1. Install photocell and wire as per diagram.
2. Use photocell rated for your supply voltage.

Trunnion

1. Mount fixture onto surface using the hole 
     pattern provided on the trunnion bracket. 
2. Loosen center bolts and set screw. 
3. Rotate fixture to desired aiming position 
     and tighten center bolts. 
4. Make wiring connection as per wire 
     diagram below.

Wall Mount

Black

White

Neutral

Green/Yellow Green

Ground

Line

Purple

DIM+

Gray

DIM-

BLACK

BLACK

BLACK

INPUT

LAMPLOAD

RED

PHOTOCONTROL

WHITE

WHITE

WHITE

Slipfitter

1.  Connect the wires to L / N / GND
2.  Remove the cover and adjust the bracket to the desired angle
3.  Install the bracket on the pole and fix it with screws

Side plate

5/16’’*1.02(inch) UNC Screws

 Twisted photocell (optional)

M8*20(mm) Screws

PM4*12(mm) Screws

5/16’’*1.02(inch) UNC Screws

 Twisted photocell (optional)

PM4*8(mm) Screws

Motion Sensor (optional)

Back plate

Side plate

1/2’’1.46(inch) UNC Screws

PM4*12(mm) Screws

KM4*10(mm) Screws

OPEN

1. Remove the side plate by loosen the screws. 
2. Fix the back plate onto the arm bracket with
    screws provided. 
3. Use the metal template provided to locate 
    footprint on the wall to drill the holes, then 
    fix the bracket on the wall with screws. 
4. Route the power cord into wall mount bracket, 
    slide the fixture onto the mounting bracket, then 
    tighten bottom screws. 
5. Make wiring connection inside of bracket and 
    replace the side plate with screws.

78mm(3.07in.)

76.2mm(3in.)

114.3mm(4.5in.)

15.88mm(0.625in.)

Ø21mm(0.827in.)

(Figure 1)

(Figure 2)

(Figure 3)