ADJUSTMENT TO FACTORY SETTINGS

When connecting the unit to the electrical supply or when 

the supply is interrupted, the indicators will flash for one 

minute whilst the system settles. Pressing any button 

during this time will start normal operation.

Internal adjustments panel 
The factory settings are shown.

LIGHT ON TIME IN MINUTES

1 to 24 minutes:     

The length of the light on time after the last detection 

during darkness. The red detector indicators will stay on for 

this time after the last detection day and night. 

PULSE COUNT/WALK TEST 

Select this symbol to assist in location alignment of the 

detector beams during daylight installations. When the 

detector beams are activated the external lights will stay on 

for a period of 6 seconds. 

1, 2 or 3

After completing the ‘walk test’ function, set the pulse count 

to required level. The pulse count is the number of detector 

beams that have to be crossed to trigger the system.

1. Will give fast response

2. Gives better immunity with good response

3. Gives highest immunity to false activation in poor 

environments but us less responsive.

The GJD Sapphire is a single area security lighting 

controller which enables external areas to be accurately 

monitored.

It automatically switches up to 1500 watts of resistive 

lighting at night for a pre-set period and can be manually 

overridden when required. The controller incorporates an 

audible warning tone and features four detector indicators 

which illuminate when activated by detection day and night.

OPERATING INSTRUCTIONS

When a detector is activated day or night the relevant 

detector indicator flickers and will remain on for the length 

of the timer setting. During darkness the lighting will be 

switched on automatically while the detector is receiving 

activation signals, and will automatically turn off after the 

pre set timer period. 

The ‘Zone 1’ green indicator has to be selected for 

automatically controlled lighting on detection during 

darkness. 

1

ZONE 1

ZONE 1

ZONE 1

Green indicator is ‘on’. This mode 

must be selected for automatic 

lighting during darkness.

Indicator ‘off’. Lighting and tone are 

switch off.

Green indicator flashing. A detector 

has activated the lighting.

Manually selecting this yellow 

indicator will turn the lighting ‘on’. 

Turning the indicator ‘off’ will return 

to automatic mode.

Indicator ‘off’.

Yellow indicator flashing. A 

detection has automatically 

activated the lighting. 

Red indicator ‘on’. Audible warning 

tone selected. Zone 1 indicator to 

be selected to function.

Indicator ‘off’ Audible warning tone 

is switched off.

LIGHT ON 

TIME MINS

PULSE 

COUNT

1

3

5

10

24

1

2

3

Sapphire 1500 MK3

GJD005 Lighting Controller

Detect

.

Illuminate

.

Deter